English
Language : 

S-201 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 200W Single Output Switching Power Supply
200W Single Output Switching Power Supply
S-201 series
■ Features :
AC input range selectable by switch
Protections: Short circuit / Overload / Over temperature
Cooling by free air convection
100% full load burn-in test
Compact size, light weight
Fixed switching frequency at 25KHz
Low cost
High reliability
1 year warranty
SPECIFICATION
MODEL
S-201-5
S-201-7.5 S-201-12
S-201-13.5 S-201-15
S-201-24
S-201-27
S-201-48
DC VOLTAGE
5V
7.5V
12V
13.5V
15V
24V
27V
48V
RATED CURRENT
40A
26.5A
16.5A
14.7A
13A
8.3A
7.4A
4.2A
CURRENT RANGE
0 ~ 40A
0 ~ 26.50A 0 ~ 16.5A
0 ~ 14.7A
0 ~ 13A
0 ~ 8.3A
0 ~ 7.4A
0 ~ 4.2A
RATED POWER
200W
198.75W
198W
198.45W
198W
199.2W
199.8W
201.6W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 240mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
4.5 ~ 5.6V
VOLTAGE TOLERANCE Note.3 ± 2.0%
LINE REGULATION
± 0.5%
LOAD REGULATION
± 1.0%
6 ~ 9V
± 2.0%
± 0.5%
± 1.0%
10 ~ 13.2V
± 1.0%
± 0.5%
± 0.5%
12 ~ 15V
± 1.0%
± 0.5%
± 0.5%
13.5 ~ 18V
± 1.0%
± 0.5%
± 0.5%
20 ~ 26.4V
± 1.0%
± 0.5%
± 0.5%
26 ~ 32V
± 1.0%
± 0.5%
± 0.5%
41 ~ 56V
± 1.0%
± 0.5%
± 0.5%
SETUP, RISE TIME
200ms, 100ms at full load
HOLD UP TIME (Typ.)
24ms at full load
VOLTAGE RANGE
90 ~ 132VAC / 180 ~ 264VAC by switch 254 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
74%
79%
80%
80%
81%
83%
83%
84%
INPUT
AC CURRENT (Typ.)
3.6A/115VAC 2A/230VAC
INRUSH CURRENT (Typ.) 45A/115VAC 45A/230VAC
LEAKAGE CURRENT
<3.5mA / 240VAC
OVERLOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
5.75 ~ 6.75V 9.4 ~ 10.9V 13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V
27.6 ~ 32.4V
Protection type : Shut down o/p voltage, re-power on to recover
≧90℃(RTH3) detect on inside ambient temperature
Protection type : Hiccup mode, recovers automatically after fault condition is removed
33.7 ~ 39.2V
57.6 ~ 67.2V
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
-10 ~ +50℃ (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85℃, 10 ~ 95% RH
± 0.03%/℃ (0 ~ 50℃)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
Design refer to UL1950
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
EMC
OTHERS
NOTE
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Design refer to FCC Part15 J Conduction Class A
MTBF
271.9K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
215*115*50mm (L*W*H)
PACKING
0.93Kg; 12pcs/12Kg/0.92CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
File Name:S-201-SPEC 2007-10-25