English
Language : 

S-150_10 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 150W Single Output Switching Power Supply
150W Single Output Switching Power Supply
S-150 series
Features :
AC input range selectable by switch
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 25KHz
2 years warranty
SPECIFICATION
MODEL
S-150-5 S-150-7.5 S-150-9 S-150-12 S-150-13.5 S-150-15 S-150-24 S-150-27 S-150-48
DC VOLTAGE
5V
7.5V
9V
12V
13.5V
15V
24V
27V
48V
RATED CURRENT
30A
20A
16.7A
12.5A
11.2A
10A
6.5A
5.6A
3.2A
CURRENT RANGE
0 ~ 30A
0 ~ 20A
0 ~ 16.7A 0 ~ 12.5A 0 ~ 11.2A 0 ~ 10A
0 ~ 6.5A 0 ~ 5.6A 0 ~ 3.2A
RATED POWER
150W
150W
150.3W
150W
151.2W
150W
156W
151.2W
153.6W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 180mVp-p 180mVp-p 180mVp-p 180mVp-p 240mVp-p 240mVp-p 240mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
4.5 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION
0.5%
6 ~ 8.3V
1.0%
0.5%
8 ~ 10.4V
1.0%
0.3%
10.6 ~ 13.2V 12 ~ 15V
1.0%
1.0%
0.3%
0.3%
13.5 ~ 16.5V 21 ~ 28V
1.0%
1.0%
0.3%
0.2%
24 ~ 30V
1.0%
0.2%
43 ~ 53V
1.0%
0.2%
LOAD REGULATION
0.5%
0.5%
0.3%
0.3%
0.3%
0.3%
0.2%
0.2%
0.2%
SETUP, RISE TIME
100ms, 50ms at full load
HOLD UP TIME (Typ.)
28ms at full load
VOLTAGE RANGE
88 ~ 132VAC/176 ~ 264VAC selected by switch 248 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
78%
80%
80%
82%
83%
84%
85%
86%
87%
3.2A/115VAC 1.6A/230VAC
INRUSH CURRENT (Typ.) COLD START 35A
LEAKAGE CURRENT
<3.5mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
105 ~ 150% rated output power
Note.5 Protection type : Shut down o/p voltage, re-power on to recover
5.75 ~ 6.75V 8.63 ~ 10.13V 10.35 ~ 12.2V 13.8 ~ 16.2V 15.53 ~ 18.2V 17.25 ~ 20.3V 30 ~ 34.8V
Protection type : Shut down o/p voltage, re-power on to recover
31.1 ~ 36.45V 55.2 ~ 64.8V
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
SAFETY &
EMC
(Note 4)
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL1012, UL60950-1, TUV EN60950-1, CCC GB4943 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
OTHERS
NOTE
MTBF
286.7K hrs min. MIL-HDBK-217F (25 )
DIMENSION
199*110*50mm (L*W*H)
PACKING
0.8Kg; 16pcs/13.8Kg/0.95CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. If the power supply is short-circuited under no load, it will recover automatically when short-circuit is removed.
File Name:S-150-SPEC 2010-10-18