English
Language : 

S-100F_10 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 100W Single Output Switching Power Supply
100W Single Output Switching Power Supply
S-100F series
Features :
AC input range selectable by switch
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 83KHz
2 years warranty
SPECIFICATION
(for 24V only)
MODEL
S-100F-5
S-100F-7.5
S-100F-12
S-100F-15
S-100F-24
S-100F-48
DC VOLTAGE
5V
7.5V
12V
15V
24V
48V
RATED CURRENT
20A
13.5A
8.5A
6.7A
4.5A
2.2A
CURRENT RANGE
0 ~ 20A
0 ~ 13.5A
0 ~ 8.5A
0 ~ 6.7A
0 ~ 4.5A
0 ~ 2.2A
RATED POWER
100W
101W
102W
100.5W
108W
105.6W
OUTPUT
RIPPLE & NOISE (max.) Note.2 100mVp-p
VOLTAGE ADJ. RANGE
4.5 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION
0.5%
125mVp-p
6.75 ~ 8.25V
1.0%
0.5%
125mVp-p
10.8 ~ 13.2V
1.0%
0.5%
125mVp-p
13.5 ~ 16.5V
1.0%
0.5%
150mVp-p
21.6 ~ 26.4V
1.0%
0.5%
150mVp-p
43.2 ~ 52.8V
1.0%
0.5%
LOAD REGULATION
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME
1000ms, 30ms at full load
HOLD UP TIME (Typ.)
20ms at full load
VOLTAGE RANGE
88 ~ 132VAC/176 ~ 264VAC selected by jumper or switch 248 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY (Typ.)
76%
78%
80%
81%
83%
84%
AC CURRENT (Typ.)
3.15A/115VAC 1.5A/230VAC
INRUSH CURRENT (Typ.) COLD START 20A/115VAC 40A/230VAC
LEAKAGE CURRENT
<1mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.75V
8.63 ~ 10.13V
13.8 ~ 16.2V
17.25 ~ 20.25V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
27.6 ~ 32.4V
55.2 ~ 64.8V
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
SAFETY &
EMC
(Note 4)
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
CSA60950-1 (for 24V only), UL1012, UL60950-1, TUV EN60950-1, CCC GB4943 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
OTHERS
NOTE
MTBF
314.9K hrs min. MIL-HDBK-217F (25 )
DIMENSION
199*98*38mm (L*W*H)
PACKING
0.65Kg; 20pcs/14.2Kg/0.8CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:S-100F-SPEC 2010-10-18