English
Language : 

RSP-750 Datasheet, PDF (1/5 Pages) Mean Well Enterprises Co., Ltd. – 750W Single Output Power Supply
750W Single Output Power Supply
RSP-750 series
SPECIFICATION
¡½ Features :
¡EUniversal AC input / Full range
¡EAC input active surge current limiting
¡EHigh efficiency up to 92%
¡EBuilt-in 12V/0.1A auxiliary power
¡EBuilt-in active PFC function, PF>0.97
¡EProtections: Short circuit / Overload / Over voltage / Over temperature / Fan
¡Ealarm
Output voltage can be trimmed between 40 ~ 110% by 2 ~ 5.5VDC external
¡Econtrol signal
Output current can be trimmed between 40 ~ 110% by 2 ~ 5.5VDC external
¡E¡E¡E¡E¡E¡E¡Econtrol signal
Forced air cooling by built-in DC with fan speed control function
High power density 9.44w/inch3
1U low profile 41mm
DC OK Signal
Built-in remote ON-OFF control
Built-in remote sense function
3 years warranty
MODEL
RSP-750-5
RSP-750-12
RSP-750-15
RSP-750-24
RSP-750-27
RSP-750-48
DC VOLTAGE
5V
12V
15V
24V
27V
48V
RATED CURRENT
100A
62.5A
50A
31.3A
27.8A
15.7A
CURRENT RANGE
0 ~ 100A
0 ~ 62.5A
0 ~ 50A
0 ~ 31.3A
0 ~ 27.8A
0 ~ 15.7A
RATED POWER
500W
750W
750W
751.2W
750.6W
753.6W
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
4.75 ~ 5.5V
¡Ó VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION
¡Ó0.5%
LOAD REGULATION
¡Ó2.0%
10 ~ 13.5V
¡Ó1.0%
¡Ó0.5%
¡Ó0.5%
13.5 ~ 16.5V
¡Ó1.0%
¡Ó0.5%
¡Ó0.5%
20 ~ 26.4V
¡Ó1.0%
¡Ó0.5%
¡Ó0.5%
24 ~ 30V
¡Ó1.0%
¡Ó0.5%
¡Ó0.5%
43 ~ 55V
¡Ó1.0%
¡Ó0.5%
¡Ó0.5%
SETUP, RISE TIME
1000ms, 50ms at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load
VOLTAGE RANGE
Note.5 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
0.97/230VAC 0.98/115VAC at full load
INPUT EFFICIENCY (Typ.)
82%
87%
89%
90.5%
90.5%
92%
AC CURRENT (Typ.)
5V : 5.6A/115VAC 2.8A/230VAC 12V~48V : 8.2A/115VAC 3.9A/230VAC
INRUSH CURRENT (Typ.) 25A/115VAC 40A/230VAC
LEAKAGE CURRENT
<2.0mA / 240VAC
OVERLOAD
105 ~ 125% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
AUXILIARY POWER(AUX)
5.75 ~ 6.75V
13.8 ~ 16.8V
17 ~ 20.5V
27.6 ~ 32.4V
31 ~ 36.5V
56.6 ~ 66.2V
¢J¡Ó ¢J ¢J¡Ó ¢J Protection type : Shut down o/p voltage, re-power on to recover
85 5 (TSW2 ) detect on heatsink of O/P diode; 80 5 (TSW1 ) detect on heatsink of power transistor
¡Ó Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
12V @ 0.1A ; tolerance : 10%
REMOTE ON/OFF CONTROL Note.6 Power on : short between on/off(pin13) & 12V-AUX(pin14) on CN50 Power off : open between on/off(pin13) & 12-AUX(pin14) on CN50
FUNCTION DC OK SIGNAL
The TTL signal out, PSU turn on = 0 ~ 1V ; PSU turn off = 3.3 ~ 5.6V
OUTPUT VOLTAGE TRIM Note.6 Adjustment of output voltage is possible between 40 ~ 110% by 2 ~ 5.5VDC external control signal
OUTPUT CURRENT TRIM
WORKING TEMP.
Adjustment of output current is between 40 ~ 110% by 2 ~ 5.5VDC external control signal
¢J -30 ~ +70 (Refer to "Derating Curve")
¢J WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
¡Ó ¢J ¢J 0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note 4) EMC EMISSION
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
¢J I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22), EN61000-3-2,-3
EMC IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
¢J 120.8K hrs min. MIL-HDBK-217F (25 )
OTHERS
NOTE
DIMENSION
250*127*41mm (L*W*H)
¢J PACKING
1.64Kg; 6pcs/10.8Kg/1.1CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. The power supply unit will have no output if the shorting connector is not assembled. It contains three shorting wires: one is from on/off(pin13) to
12V-AUX(pin14), two is from PC(pin7) to PO(pin8) and the other is from PV(pin5) to PS(pin6). Please refter to function manual for details.
7. Please consult MEAN WELL for applications of more units connecting in parallel.
File Name:RSP-750-SPEC 2012-08-27