English
Language : 

RSP-200 Datasheet, PDF (1/3 Pages) Mean Well Enterprises Co., Ltd. – 200W Single Output with PFC Function
200W Single Output with PFC Function
RSP-200 series
¡½ Features :
¡EUniversal AC input / Full range
¡EBuilt-in active PFC function, PF>0.95
¡EHigh efficiency up to 90%
¡EProtections: Short circuit / Overload / Over voltage / Over temperature
¡ECooling by free air convection
¡E1U low profile 30mm
¡EOptional conformal coating models (RSP-200-¡¼CC)
¡ELED indicator for power on
¡E3 years warranty
SPECIFICATION
MODEL
RSP-200-2.5
RSP-200-3.3
RSP-200-4
RSP-200-5
RSP-200-7.5
RSP-200-12
DC VOLTAGE
2.5V
3.3V
4V
5V
7.5V
12V
RATED CURRENT
40A
40A
40A
40A
26.7A
16.7A
CURRENT RANGE
0 ~ 40A
0 ~ 40A
0 ~ 40A
0 ~ 40A
0 ~ 26.7A
0 ~ 16.7A
RATED POWER
100W
132W
160W
200W
200.25W
200.4W
OUTPUT
RIPPLE & NOISE (max.) Note.2 100mVp-p
100mVp-p
100mVp-p
150mVp-p
VOLTAGE ADJ. RANGE
2.35 ~ 2.85V
2.97 ~ 3.8V
3.7 ~ 4.3V
4.5 ~ 5.5V
VOLTAGE TOLERANCE Note.3 ¡Ó2.0%
¡Ó2.0%
¡Ó2.0%
¡Ó2.0%
LINE REGULATION
¡Ó0.5%
¡Ó0.5%
¡Ó0.5%
¡Ó0.5%
LOAD REGULATION
¡Ó1.5%
¡Ó1.5%
¡Ó1.0%
¡Ó1.0%
SETUP, RISE TIME
1500ms, 50ms/230VAC 3000ms, 50ms/115VAC at full load
150mVp-p
6 ~ 9V
¡Ó2.0%
¡Ó0.5%
¡Ó1.0%
150mVp-p
10 ~ 13.2V
¡Ó1.0%
¡Ó0.3%
¡Ó0.5%
HOLD UP TIME (Typ.)
8ms at full load 230VAC /115VAC
INPUT
VOLTAGE RANGE Note.4 88 ~ 264VAC 124 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC PF>0.98/115VAC at full load
EFFICIENCY (Typ.)
81.5%
84%
85.5%
AC CURRENT (Typ.)
2A/115VAC 1.1A/230VAC
INRUSH CURRENT (Typ.) 20A/115VAC 40A/230VAC
87%
89%
89%
3.5A/115VAC 1.7A/230VAC
LEAKAGE CURRENT
<1mA / 240VAC
OVERLOAD
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
2.88 ~ 3.5V
3.8 ~ 4.62V
4.5 ~ 5.6V
5.75 ~ 7V
Protection type : Shut down o/p voltage, re-power on to recover
9.4 ~ 10.9V
OVER TEMPERATURE
110¢J ¡Ó5¢J(TSW1) detect on heatsink of main power output choke
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
-30 ~ +70¢J (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85¢J, 10 ~ 95% RH
TEMP. COEFFICIENT
¡Ó0.03%/¢J (0 ~ 45¢J)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
13.8 ~ 16.2V
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note 5) EMC EMISSION
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25¢J/ 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
MTBF
224.5K hrs min. MIL-HDBK-217F (25¢J)
OTHERS DIMENSION
215*115*30mm (L*W*H)
PACKING
0.72Kg; 15pcs/11.8Kg/0.78CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¢J of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:RSP-200-SPEC 2012-12-28