English
Language : 

RSD-200_12 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 200W Railway Single Output DC-DC Converter
200W Railway Single Output DC-DC Converter
RSD-200 series
Features :
2:1 wide input range
Protections: Short circuit / Overload / Over voltage / Over temperature
/ Input reverse polarity
4000VDC I/O isolation
Cooling by free air convection
Built-in constant current limiting circuit
1U low profile 39mm
Compliance to EN50155 railway standard
All using 105 long life electrolytic capacitors
LED indicator for power on
100% full load burn-in test
SPECIFICATION
3 years warranty
MODEL
RSD-200B-12 RSD-200B-24 RSD-200B-48 RSD-200C-12 RSD-200C-24 RSD-200C-48 RSD-200D-12 RSD-200D-24 RSD-200D-48
DC VOLTAGE
12V
24V
48V
12V
24V
48V
12V
24V
48V
RATED CURRENT
16.7A
8.4A
4.2A
16.7A
8.4A
4.2A
16.7A
8.4A
4.2A
CURRENT RANGE
0 ~ 16.7A 0 ~ 8.4A 0 ~ 4.2A 0 ~ 16.7A 0 ~ 8.4A 0 ~ 4.2A 0 ~ 16.7A 0 ~ 8.4A 0 ~ 4.2A
RATED POWER
200.4W
201.6W 201.6W
200.4W
201.6W
201.6W
200.4W
201.6W
201.6W
OUTPUT
RIPPLE & NOISE (max.) Note.2 120mVp-p
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION
0.2%
150mVp-p
2.0%
0.2%
180mVp-p
2.0%
0.5%
120mVp-p
2.0%
0.2%
150mVp-p
2.0%
0.2%
180mVp-p
2.0%
0.5%
120mVp-p
2.0%
0.2%
150mVp-p
2.0%
0.2%
180mVp-p
2.0%
0.5%
LOAD REGULATION
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
SETUP, RISE TIME
800ms, 50ms at full load
HOLD UP TIME (Typ.)
3 ~ 30ms @ full load ; B/C- type comply with S1 level ; D-type comply with S2 level
INPUT
VOLTAGE CONTINUOUS
RANGE 1 SEC.
EFFICIENCY (Typ.)
DC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
16.8 ~ 31.2VDC
14.4 ~ 33.6VDC
89%
89%
9.6A/24V 9.6A/24V
45A/24VDC
89%
9.6A/24V
33.6 ~ 62.4VDC
28.8 ~ 67.2VDC
91%
91%
4.8A/48V 4.8A/48V
45A/48VDC
91%
4.8A/48V
67.2 ~ 143VDC
57.6 ~ 154VDC
91%
91%
2.1A/110V 2.1A/110V
45A/110VDC
91%
2.1A/110V
OVERLOAD
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
13.8 ~ 16.2V 27.6 ~ 32.4V 55.2 ~ 64.8V 13.8 ~ 16.2V 27.6 ~ 32.4V 55.2 ~ 64.8V 13.8 ~ 16.2V 27.6 ~ 32.4V 55.2 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
90 5 (TSW1) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
RAILWAY STANDARD
-40 ~ +55 (no derating) ; +70 @ 60% load by free air convection ; +70 (no derating with external base plate)
20 ~ 95% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373
Meet IEC60950-1(LVD)
I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Conduction Emission: Class A, Radiation Emission: Class B ; EN50155(EN50121-3-2)
Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A ; EN50121-3-2
Meet EN50155 / IEC60571 including IEC61373 for shock & vibration, EN50121-3-2 for EMC
OTHERS
NOTE
MTBF
218.2K hrs min. MIL-HDBK-217F (25 )
DIMENSION
191*86*40mm (L*W*H)
PACKING
0.94Kg; 12pcs/12.3Kg/0.8CUFT
1. All parameters NOT specially mentioned are measured at 24,48,110VDC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:RSD-200-SPEC 2012-03-09