English
Language : 

RSD-150 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 150W Railway Single Output DC-DC Converter
150W Railway Single Output DC-DC Converter
RSD-150 series
Features :
2:1 wide input range
Protections: Short circuit / Overload / Over voltage / Over temperature
/ Input reverse polarity
4000VDC I/O isolation
Cooling by free air convection
Built-in constant current limiting circuit
1U low profile 36mm
Compliance to EN50155 railway standard
All using 105 long life electrolytic capacitors
LED indicator for power on
100% full load burn-in test
3 years warranty
SPECIFICATION
MODEL
RSD-150B-5 RSD-150B-12 RSD-150B-24 RSD-150C-5 RSD-150C-12 RSD-150C-24 RSD-150D-5 RSD-150D-12 RSD-150D-24
DC VOLTAGE
5V
12V
24V
5V
12V
24V
5V
12V
24V
RATED CURRENT
30A
12.5A
6.3A
30A
12.5A
6.3A
30A
12.5A
6.3A
CURRENT RANGE
0 ~ 30A
0 ~ 12.5A 0 ~ 6.3A 0 ~ 30A
0 ~ 12.5A 0 ~ 6.3A 0 ~ 30A
0 ~ 12.5A 0 ~ 6.3A
RATED POWER
150W
150W
151.2W
150W
150W
151.2W
150W
150W
151.2W
RIPPLE & NOISE (max.) Note.2 100mVp-p
OUTPUT
VOLTAGE TOLERANCE Note.3 2.0%
120mVp-p 150mVp-p 100mVp-p 120mVp-p 150mVp-p 100mVp-p 120mVp-p 150mVp-p
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
LINE REGULATION
0.5%
0.3%
0.2%
0.5%
0.3%
0.2%
0.5%
0.2%
0.2%
LOAD REGULATION
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
SETUP, RISE TIME
800ms, 50ms at full load
HOLD UP TIME (Typ.)
3 ~ 30ms @ full load ; B/C- type comply with S1 level ; D-type comply with S2 level
VOLTAGE CONTINUOUS 16.8 ~ 31.2VDC
RANGE 1 SEC.
14.4 ~ 33.6VDC
33.6 ~ 62.4VDC
28.8 ~ 67.2VDC
67.2 ~ 143VDC
57.6 ~ 154VDC
INPUT EFFICIENCY (Typ.)
89%
90%
90%
90%
92%
91%
90%
92%
91%
DC CURRENT (Typ.)
7.3A/24V 7.3A/24V 7.3A/24V 3.6A/48V 3.6A/48V 3.6A/48V 1.5A/110V 1.5A/110V 1.5A/110V
INRUSH CURRENT (Typ.) 45A/24VDC
45A/48VDC
45A/110VDC
OVERLOAD
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
5.75 ~ 7V 13.8 ~ 16.2V 27.6 ~ 32.4V 5.75 ~ 7V 13.8 ~ 16.2V 27.6 ~ 32.4V 5.75 ~ 7V
Protection type : Shut down o/p voltage, re-power on to recover
115 5 (TSW1) detect on main power transformer
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
13.8 ~ 16.2V 27.6 ~ 32.4V
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-40 ~ +55 (no derating) ; +70
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
@ 60% load by free air convection ; +70
(no derating with external base plate)
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373
SAFETY STANDARDS
Meet IEC60950-1(LVD)
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Conduction Emission: Class A, Radiation Emission: Class B ; EN50121-3-2
Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A ; EN50121-3-2
RAILWAY STANDARD
Meet EN50155 / IEC60571 including IEC61373 for shock & vibration, EN50121-3-2 for EMC
MTBF
OTHERS DIMENSION
223.2K hrs min. MIL-HDBK-217F (25 )
189*77*36mm (L*W*H)
NOTE
PACKING
0.8Kg; 15pcs/13Kg/0.75CUFT
1. All parameters NOT specially mentioned are measured at 24,48,110VDC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:RSD-150-SPEC 2011-12-01