English
Language : 

RS-150_10 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 150W Single Output Switching Power Supply
150W Single Output Switching Power Supply
RS-150 series
Features :
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105 long life electrolytic capacitors
Withstand 300VAC surge input for 5 second
High operating temperature up to 70
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
SPECIFICATION
MODEL
RS-150-3.3
RS-150-5
RS-150-12
RS-150-15
RS-150-24
RS-150-48
OUTPUT
INPUT
DC VOLTAGE
3.3V
5V
12V
15V
24V
48V
RATED CURRENT
30A
26A
12.5A
10A
6.5A
3.3A
CURRENT RANGE
0 ~ 30A
0 ~ 26A
0 ~ 12.5A
0 ~ 10A
0 ~ 6.5A
0 ~ 3.3A
RATED POWER
99W
130W
150W
150W
156W
158.4W
RIPPLE & NOISE (max.) Note.2 80mVp-p
80mVp-p
120mVp-p
120mVp-p
120mVp-p
200mVp-p
VOLTAGE ADJ. RANGE
3.2V ~ 3.5V
4.75 ~ 5.5V
11.4 ~ 13.2V
14.25 ~ 16.5V
22.8 ~ 26.4V
45.6 ~ 52.8V
VOLTAGE TOLERANCE Note.3 3.0%
2.0%
1.0%
1.0%
1.0%
1.0%
LINE REGULATION Note.4 0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION Note.5 2.0%
1.0%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME
800ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)
28ms/230VAC 20ms/115VAC at full load
VOLTAGE RANGE
88 ~ 132VAC / 176 ~ 264VAC selected by switch 248 ~ 373VDC(Withstand 300VAC surge for 5sec. Without damage)
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY(Typ.)
74%
78%
83%
84%
86%
87%
AC CURRENT (Typ.)
3A/115VAC 2A/230VAC
INRUSH CURRENT (Typ.) COLD START 40A/230VAC
LEAKAGE CURRENT
<2mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
110 ~ 150% rated output power
Note.8 Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.8 ~ 4.45V
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
27.6 ~ 32.4V
55.2 ~ 64.8V
WORKING TEMP.
-25 ~ +70 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
SAFETY &
EMC
(Note 6)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
MTBF
244KHrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
199*98*38mm (L*W*H)
NOTE
PACKING
0.7Kg; 20pcs/15Kg/0.8CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
8. Extra consideration should be taken when selecting output wiring for 3.3V and 5V models. This is to prevent the protection modes for overload and short
circuit from becoming constant power.
File Name:RS-150-SPEC 2010-10-18