RQ-65_10 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 65W Quad Output Switching Power Supply
65W Quad Output Switching Power Supply
RQ-65 series
Features :
Universal AC input / Full range
Protections:Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105 long life electrolytic capacitors
Withstand 300VAC surge input for 5 second
High operating temperature up to 70
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
..
SPECIFICATION
MODEL
RQ-65B
RQ-65C
RQ-65D
OUTPUT
OUTPUT NUMBER
CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4
DC VOLTAGE
5V
12V
-5V
-12V 5V
15V
-5V
-15V 5V
12V
24V
-12V
RATED CURRENT
6A
2A
0.5A 0.5A 5A
2A
0.5A 0.5A 4A
1.5A 1A
0.5A
CURRENT RANGE Note.6 0.5 ~ 8A 0.2 ~ 3A 0 ~ 1A 0 ~ 1A 0.5 ~ 8A 0.2 ~ 3A 0 ~ 1A 0 ~ 1A 0.5 ~ 8A 0.2 ~ 3A 0.1 ~ 1.5A 0 ~ 1A
RATED POWER
Note.6 62.5W
65W
68W
RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 80mVp-p 80mVp-p 80mVp-p 120mVp-p 80mVp-p 80mVp-p 80mVp-p 120mVp-p 180mVp-p 80mVp-p
VOLTAGE ADJ. RANGE
CH1: 4.75 ~ 5.5V
CH1: 4.75 ~ 5.5V
CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0% +7,-5% 5.0% 5.0% 2.0% +10,-4% 5.0% 5.0% 2.0% 6.0% 8.0% 5.0%
LINE REGULATION Note.4 0.5% 1.5% 0.5% 0.5% 0.5% 1.5% 0.5% 0.5% 0.5% 1.5% 2.0% 0.5%
LOAD REGULATION Note.5 0.5% 3.0% 1.0% 1.0% 0.5% 4.0% 1.0% 1.0% 0.5% 3.0% 5.0% 1.0%
SETUP, RISE TIME
500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)
60ms/230VAC 14ms/115VAC at full load
INPUT
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
47 ~ 63Hz
76%
76%
78%
2A/115VAC 1.2A/230VAC
COLD START 40A/230VAC
LEAKAGE CURRENT
<2mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
WORKING TEMP.
-25 ~ +70 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )on +5V output
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
SAFETY &
EMC
(Note 7)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
245.5Khrs min. MIL-HDBK-217F (25 )
OTHERS
NOTE
DIMENSION
129*98*38mm (L*W*H)
PACKING
0.44Kg; 30pcs/13.2Kg/0.72CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:RQ-65-SPEC 2010-10-18