65W Triple Output Switching Power Supply
RPT-65 series
Features :
Universal AC input/Full range
12V or 24V high peak output current capability
Optional L-Bracket and cover (RPT-65x-C, x=E,F,G)
Low leakage current<1mA
Protections: Short circuit / Overload / Over voltage
65W free air convection, 80W with 18CFM forced air
100% full load burn-in test
Fixed switching frequency at 65KHz
2 years warranty
SPECIFICATION
MODEL
RPT-65E
RPT-65F
RPT-65G
OUTPUT NUMBER
CH1
CH2
CH3
CH1
CH2
CH3
CH1
CH2
CH3
DC VOLTAGE
12V
5V
-5V
12V
5V
-12V
24V
5V
12V
RATED CURRENT
4.5A
1.2A
0.5A
4.5A
1.2A
0.5A
2.25A
1.2A
0.5A
CURRENT RANGE
0.18 ~ 5.8A 0 ~ 1.5A 0 ~ 0.7A 0.18 ~ 5.8A 0 ~ 1.5A 0 ~ 0.7A 0.09 ~ 2.9A 0 ~ 1.5A 0 ~ 0.7A
PEAK LOAD
Note.4 7.5A
Rated load Rated load 7.5A
Rated load Rated load 3.75A
Rated load Rated load
RATED POWER
62.5W
66W
66W
OUTPUT OUTPUT POWER (max.)
Rated output power for convection; 80W with 18CFM min. forced air
RIPPLE & NOISE (max.) Note.2 120mVp-p 100mVp-p
VOLTAGE ADJ. RANGE
CH1:11.4 ~ 12.8V
VOLTAGE TOLERANCE Note.3 2.0%
5.0%
LINE REGULATION
1.0%
1.0%
120mVp-p
5.0%
1.0%
150mVp-p 100mVp-p
CH1:11.4 ~ 12.8V
2.0%
5.0%
1.0%
1.0%
150mVp-p
5.0%
1.0%
150mVp-p 50mVp-p
CH1:22.8 ~ 26.4V
2.0%
5.0%
1.0%
1.0%
100mVp-p
5.0%
1.0%
LOAD REGULATION
2.0%
5.0%
5.0%
2.0%
5.0%
5.0%
2.0%
5.0%
5.0%
SETUP, RISE TIME
800ms, 20ms at full load
HOLD UP TIME (Typ.)
20ms at full load
VOLTAGE RANGE
90 ~ 264VAC 127 ~370VDC
FREQUENCY RANGE
47 ~ 440Hz
INPUT
EFFICIENCY (Typ.)
77%
77%
81%
AC CURRENT (Typ.)
1.5A/115VAC 0.9A/230VAC
INRUSH CURRENT (Typ.) COLD START 25A/115VAC 50A/230VAC
LEAKAGE CURRENT
<1mA
OVERLOAD
PROTECTION
OVER VOLTAGE
90 ~ 125W output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
CH1:13.8 ~ 16.2V
CH1:13.8 ~ 16.2V
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
CH1:27.6 ~ 32.4V
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note 5) EMC EMISSION
-20 ~ +60 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.04%/ (0 ~ 50 ) on CH1 output
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
OTHERS
NOTE
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
MTBF
288.1K hrs min. MIL-HDBK-217F (25 )
DIMENSION
PCB:127*76*28mm (L*W*H) ; with optional CASE:130*85*37mm (L*W*H)
PACKING
PCB:0.24Kg; 63pcs/16Kg/1.35CUFT ; with optional CASE:0.47Kg;32pcs/16Kg/0.64CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 10% duty cycle maximum within every second. Average output power should not exceed the rated power, output voltage above 90% DC voltage.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:RPT-65-SPEC 2011-08-19