RPS-75 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 75W Single Output Medical Type
75W Single Output Medical Type
RPS-75 series
Features :
Universal AC input/Full range
Low leakage current<200uA
Protections: Short circuit / Overload / Over voltage
Free air convection for rated power and 23.5CFM forced air
convection for peak load
UL60601-1/IEC60601-1/EN60601-1 medical safety approved
No load power consumption<0.75W
Fixed switching frequency at 65KHz
3 years warranty
SPECIFICATION
EN60601-1
IEC60601-1
MODEL
RPS-75-3.3
RPS-75-5
RPS-75-12
RPS-75-15
RPS-75-24
RPS-75-36
RPS-75-48
OUTPUT
INPUT
DC VOLTAGE
3.3V
5V
12V
15V
24V
RATED CURRENT
15A
14A
6.3A
5A
3.2A
CURRENT RANGE
0 ~ 20A
0 ~ 18.7A
0 ~ 8.3A
0 ~ 6.7A
0 ~ 4.2A
RATED POWER
49.5W
70W
75.6W
75W
76.8W
PEAK LOAD (23.5CFM)
66W
94W
99.6W
100.5W
100.8W
RIPPLE & NOISE (max.) Note.2 80mVp-p
80mVp-p
120mVp-p
150mVp-p
240mVp-p
VOLTAGE ADJ. RANGE
2.9 ~ 3.6V
4.75 ~ 5.5V
11.4 ~ 13.2V
13.5 ~ 16.5V 22.8 ~ 27.6V
VOLTAGE TOLERANCE Note.3 2.0%
2.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
1.5%
1.5%
1.0%
1.0%
1.0%
SETUP, RISE TIME
500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)
80ms/230VAC 20ms/115VAC at full load
VOLTAGE RANGE
90 ~ 264VAC 127 ~370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY(Typ.)
73%
78%
82%
83%
85%
AC CURRENT (Typ.)
1.5A/115VAC 1A/230VAC
INRUSH CURRENT (Typ.) COLD START 25A/115VAC 50A/230VAC
LEAKAGE CURRENT
Earth leakage current <200uA / 264VAC, Patient leakage current <100uA/264VAC
36V
2.1A
0 ~ 2.8A
75.6W
100.8W
300mVp-p
34.2 ~ 39.6V
1.0%
0.5%
1.0%
86%
48V
1.6A
0 ~ 2.1A
76.8W
100.8W
300mVp-p
45.6 ~ 52.8V
1.0%
0.5%
1.0%
86%
OVERLOAD
PROTECTION
OVER VOLTAGE
140 ~ 180% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
3.8 ~ 4.46V
5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V
Protection type : Shut down o/p voltage, re-power to recover
WORKING TEMP.
-20 ~ +70 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 45
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60601-1, TUV EN60601-1, IEC60601-1 approved
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
41.4 ~ 48.6V
55.2 ~ 64.8V
OTHERS
NOTE
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61000-6-2, EN61204-3, heavy industry level, EN61204-3 medical level, criteria A
MTBF
446.8K hrs min. MIL-HDBK-217F (25 )
DIMENSION
127*76.2*31mm (L*W*H)
PACKING
0.23Kg; 63pcs/15.5Kg/1.35CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:RPS-75-SPEC 2008-03-25