English
Language : 

RPD-65_10 Datasheet, PDF (1/3 Pages) Mean Well Enterprises Co., Ltd. – 65W Dual Output Switching Power Supply
65W Dual Output Switching Power Supply
RPD-65 series
Features :
Universal AC input/Full range
12V or 24V high peak output current capability
Optional L-Bracket and cover (RPD-65x-C, x=C,D)
Low leakage current<1mA
Protections: Short circuit / Overload / Over voltage
60W free air convection, 77W with 18CFM forced air
100% full load burn-in test
Fixed switching frequency at 65KHz
2 years warranty
SPECIFICATION
MODEL
RPD-65C
RPD-65D
OUTPUT NUMBER
CH1
CH2
CH1
CH2
DC VOLTAGE
12V
5V
24V
5V
RATED CURRENT
4.5A
1.2A
2.25A
1.2A
CURRENT RANGE
0 ~ 5.8A
0 ~ 1.5A
0 ~ 2.9A
0 ~ 1.5A
OUTPUT
PEAK LOAD
Note.4 7.5A
Rated load
3.75A
RATED POWER
60W
60W
OUTPUT POWER (max.)
Rated output power for convection; 77W with 18CFM min. forced air
Rated load
RIPPLE & NOISE (max.) Note.2 120mVp-p
VOLTAGE ADJ. RANGE
CH1:11.4 ~ 12.8V
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION
1.0%
50mVp-p
5.0%
1.0%
150mVp-p
CH1:22.8 ~ 26.4V
2.0%
1.0%
50mVp-p
5.0%
1.0%
LOAD REGULATION
2.0%
5.0%
2.0%
5.0%
SETUP, RISE TIME
800ms, 20ms at full load
HOLD UP TIME (Typ.)
20ms at full load
VOLTAGE RANGE
90 ~ 264VAC 127 ~370VDC
FREQUENCY RANGE
47 ~ 440Hz
INPUT
EFFICIENCY (Typ.)
79%
81%
AC CURRENT (Typ.)
1.5A/115VAC 0.9A/230VAC
INRUSH CURRENT (Typ.) COLD START 25A/115VAC 50A/230VAC
LEAKAGE CURRENT
<1mA
OVERLOAD
PROTECTION
OVER VOLTAGE
90 ~ 125W output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
CH1:13.8 ~ 16.2V
CH1:27.6 ~ 32.4V
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
WORKING TEMP.
-20 ~ +60 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.04%/ (0 ~ 50 ) on CH1 output
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
SAFETY &
EMC
(Note 5)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
OTHERS
NOTE
MTBF
288.1K hrs min. MIL-HDBK-217F (25 )
DIMENSION
PCB:127*76*28mm (L*W*H) ; with optional CASE:130*85*37mm (L*W*H)
PACKING
PCB:0.24Kg; 63pcs/16Kg/1.35CUFT ; with optional CASE:0.47Kg;32pcs/16Kg/0.64CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 10% duty cycle maximum within every second. Average output power should not exceed the rated power, output voltage above 90% DC voltage.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:RPD-65-SPEC 2010-10-18