Features :
Isolated output & GND for CH1,CH2
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105 long life electrolytic capacitors
Withstand 300VAC surge input for 5 second
High operating temperature up to 70
Withstand 5G vibration test
High efficiency, long life and high reliability
SPECIFICATION
3 years warranty
MODEL
RID-50A
RID-50B
OUTPUT NUMBER
CH1
CH2
CH1
CH2
DC VOLTAGE
5V
12V
5V
24V
RATED CURRENT
6A
2A
4A
1.4A
CURRENT RANGE
0.3 ~ 6A
0.3 ~ 3A
0.3 ~ 6A
0.2 ~ 2A
OUTPUT
RATED POWER
54W
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE ADJ. RANGE
CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION Note.4 0.5%
LOAD REGULATION Note.5 0.5%
SETUP, RISE TIME
500ms, 20ms/230VAC
120mVp-p
8.0%
1.5%
5.0%
1200ms, 30ms/115VAC at full load
53.6W
80mVp-p
CH1: 4.75 ~ 5.5V
2.0%
0.5%
0.5%
150mVp-p
+8,-4%
1.5%
5.0%
HOLD UP TIME (Typ.)
60ms/230VAC 14ms/115VAC at full load
VOLTAGE RANGE
FREQUENCY RANGE
88 ~ 264VAC
47 ~ 63Hz
125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
INPUT
EFFICIENCY (Typ.)
80%
81%
AC CURRENT (Typ.)
1.3A/115VAC 0.8A/230VAC
INRUSH CURRENT (Typ.) COLD START 33A/230VAC
LEAKAGE CURRENT
<2mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
WORKING TEMP.
-25 ~ +70 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )on +5V output
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
SAFETY &
EMC
(Note 6)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
MTBF
172.6Khrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
99*97*36mm (L*W*H)
PACKING
0.41Kg; 45pcs/19.5Kg/0.9CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:RID-50-SPEC 2010-10-18