RID-125_10 Datasheet, PDF (1/3 Pages) Mean Well Enterprises Co., Ltd. – 125W Dual Output Switching Power Supply
125W Dual Output Switching Power Supply
RID-125 series
Features :
Isolated output & GND for CH1,CH2
AC input range selectable by switch
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage
All using 105 long life electrolytic capacitors
Withstand 5G vibration test
LED indicator for power on
100% full load burn-in test
High realibility
3 years warranty
SPECIFICATION
MODEL
RID-125-1224
RID-125-1248
RID-125-2448
OUTPUT
INPUT
OUTPUT NUMBER
CH1
CH2
CH1
CH2
CH1
DC VOLTAGE
12V
24V
12V
48V
24V
RATED CURRENT
3.7A
3.7A
2.3A
2.3A
2A
CURRENT RANGE Note.6 1 ~ 7A
0.4 ~ 5A
1 ~ 7A
0.2 ~ 2.5A
0.5 ~ 4A
RATED POWER
Note.6 133.2W
138W
144W
RIPPLE & NOISE (max.) Note.2 120mVp-p
200mVp-p
120mVp-p
240mVp-p
200mVp-p
VOLTAGE ADJ. RANGE
CH1: 11.4 ~ 13.2V
CH1: 11.4 ~ 13.2V
CH1: 22.8 ~ 26.4V
VOLTAGE TOLERANCE Note.3 2.0%
+8,-5%
2.0%
+8,-5%
1.0%
LINE REGULATION Note.4 0.5%
1.0%
0.5%
1.0%
0.5%
LOAD REGULATION Note.5 1.0%
5.0%
1.0%
5.0%
1.0%
SETUP, RISE TIME
500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)
36ms/230VAC 30ms/115VAC at full load
VOLTAGE RANGE
88 ~ 132VAC / 176 ~ 264VAC selected by switch 248 ~ 373VDC(300VAC peak 5sec. No damage)
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY(Typ.)
85%
85%
86%
AC CURRENT (Typ.)
3A/115VAC 2A/230VAC
INRUSH CURRENT (Typ.) COLD START 40A/230VAC
LEAKAGE CURRENT
<2mA / 240VAC
CH2
48V
2A
0.2 ~ 2.5A
240mVp-p
4.0%
1.0%
3.0%
OVERLOAD
PROTECTION
OVER VOLTAGE
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 13.8 ~ 16.2V
CH1: 13.8 ~ 16.2V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 27.6 ~ 32.4V
WORKING TEMP.
WORKING HUMIDITY
-20 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )on CH1 output
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
SAFETY &
EMC
(Note 7)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
MTBF
218.2Khrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
199*98*38mm (L*W*H)
PACKING
0.7Kg; 20pcs/15Kg/0.8CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
File Name:RID-125-SPEC 2010-10-18