RCP-2000 Datasheet, PDF (1/5 Pages) Mean Well Enterprises Co., Ltd. – 2000W Front End Power Supply
2000W Front End Power Supply
RCP-2000 series
Features :
Universal AC input / Full range
Built-in 5V/0.3A, 12V/0.8A auxiliary power
Built-in active PFC function, PF>0.98
High efficiency up to 92%
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage / Over temperature
High Power density 21.4W/inch3
Forced air cooling by built-in DC fan with fan speed control
Low profile:1U height
Remote control for single unit
Built-in remote sense function
Output voltage trimming function
Hot-swap operation
PMBus serial communication
AC OK, DC OK signal, fan fail, OTP alarm signal
Internal OR-ing FET
3 years warranty
Description :
The RCP-2000 series are state of the art AC/DC frond-end rectifiers with 1U compact size and 21.4 W/in3 of high power density. They can
provide up to 2000W per unit for the applications of servers, information technology equipment, networking, telecommunications, and wide
range of industrial applications using distributed power architecture. Equipped with hot-swap function and PMBus communication protocol,
RCP-2000 can be assembled in 1U 19” rack and controlled/monitored by external device such as monitoring unit (RCP-CMU-1) or PC.
SPECIFICATION - Single Unit
MODEL
RCP-2000-12
RCP-2000-24
RCP-2000-48
OUTPUT
INPUT
DC VOLTAGE
12V
24V
RATED CURRENT
100A
80A
CURRENT RANGE
0 ~ 100A
0 ~ 80A
RATED POWER
1200W
1920W
RIPPLE & NOISE (max.) Note.2 150mVp-p
200mVp-p
VOLTAGE ADJ. RANGE
10.5 ~ 14V
21 ~ 28V
VOLTAGE TOLERANCE Note.3 2.0%
1.0%
LINE REGULATION
1.0%
0.5%
LOAD REGULATION
1.0%
0.5%
SETUP, RISE TIME
1500ms, 60ms/230VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC at 75% load 10ms/230VAC at full load
VOLTAGE RANGE
Note.5 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
0.98/230VAC at full load
EFFICIENCY (Typ.)
86%
90.5%
AC CURRENT (Typ.)
13A/115VAC 7A/230VAC
16A/115VAC
INRUSH CURRENT (Typ.) COLD START 50A
LEAKAGE CURRENT
<1.1mA / 230VAC
10A/230VAC
48V
42A
0 ~ 42A
2016W
300mVp-p
42 ~ 56V
1.0%
0.5%
0.5%
92%
16A/115VAC
10A/230VAC
OVERLOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
AUXILIARY POWER
REMOTE ON/OFF CONTROL
REMOTE SENSE
DC OK SIGNAL
FUNCTION
AC OK SIGNAL
OUTPUT VOLTAGE TRIM
OVER TEMP WARNING
FAN FAIL SIGNAL
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
105 ~ 125% rated output power
Protection type : Constant current limiting, unit will shut down o/p voltage after 5 sec. re-power on to recover
14.7 ~ 17.5V
29.5 ~ 35V
57.6 ~ 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
80 5 (TSW1) detect on heatsink of power bridge 85 5 (TSW2) detect on heatsink of o/p diode
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
5V @ 0.3A, 12V @ 0.8A
By electrical signal or dry contact ON:short OFF:open
Compensate voltage drop on the load wiring up to 0.5V
The isolated TTL signal out, refer to function manual
The isolated TTL signal out, refer to function manual
Adjustment of output voltage, possible between 90 ~ 110% of rated output
Logic " High" for over temperature warning, refer to function manual, isolated signal
The isolated TTL signal out, refer to function manual
-40 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
File Name:RCP-2000-SPEC 2011-05-09