320W Quad Output with PFC Function
QP-320 series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
CH1 & CH2 can be adjusted from -5% ~ +10%
With power good and fail signal output
Built-in remote sense function for CH1 & CH2
LED indicator for power on
100% full load burn-in test
20A peak load capability for 24V channel
3 years warranty
..
SPECIFICATION
MODEL
QP-320D
QP-320F
OUTPUT NUMBER
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
DC VOLTAGE
5V
12V
24V
-12V
5V
15V
24V
-15V
RATED CURRENT
20A
10A
3A
2A
20A
8A
3A
1.6A
CURRENT RANGE
2.5 ~ 20A
0 ~ 10A
0.2 ~ 5A
0.2 ~ 2A
2.5 ~ 20A
0 ~ 10A
0.2 ~ 5A
0.2 ~ 1.6A
PEAK CURRENT
20A
10A
20A, 1ms(Note5) 2A
20A
10A
20A, 1ms(Note5) 1.6A
OUTPUT
RATED POWER
316W
RIPPLE & NOISE (max.) Note.2 100mVp-p 150mVp-p
VOLTAGE ADJ. RANGE
CH1,2:+10,-5%
VOLTAGE TOLERANCE Note.3 3.0%
3.0%
LINE REGULATION
1.0%
2.0%
150mVp-p
+10,-6%
2.0%
150mVp-p
10%
3.0%
100mVp-p
3.0%
1.0%
150mVp-p
3.0%
2.0%
150mVp-p
+10,-6%
2.0%
150mVp-p
10%
3.0%
LOAD REGULATION
2.0%
3.0%
6.0%
8.0%
2.0%
3.0%
6.0%
8.0%
SETUP, RISE TIME
800ms, 50ms at full load
HOLD UP TIME (Typ.)
16ms at full load
VOLTAGE RANGE
90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
PF>0.95/230VAC
83%
PF>0.98/115VAC at full load
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
4A/115VAC 2A/230VAC
25A/115VAC 45A/230VAC
LEAKAGE CURRENT
<2mA / 240VAC
OVERLOAD
PROTECTION OVER VOLTAGE
105 ~ 150% rated output power
Protection type : Fold back current limiting, recovers automatically after fault condition is removed
CH1:5.75 ~ 6.75V CH2:13.8 ~ 16.2V
CH1:5.75 ~ 6.75V CH2:17.25 ~ 20.25V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
95 5 (TSW1 )detect on heatsink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION POWER GOOD / POWER FAIL 10ms/1ms
WORKING TEMP.
-10 ~ +70 (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
TEMP. COEFFICIENT
0.03%/ (0 ~ 50
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC EMISSION
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
MTBF
213.5K hrs min. MIL-HDBK-217F (25 )
DIMENSION
215*115*50mm (L*W*H)
PACKING
1.2Kg; 12pcs/15.4Kg/0.92CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Every output channel can provide up to the maximum current, but total load can't exceed the rated output power.
6. CH3(24V) peak current 20A, 1ms, repeatable in every 100ms. CH3(24V) output must be above 16V in the period of peak current.
File Name:QP-320-SPEC 2011-08-19