QP-150_11 Datasheet, PDF (1/5 Pages) Mean Well Enterprises Co., Ltd. – 150W Quad Output with PFC Function
150W Quad Output with PFC Function
QP-150 series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Over load / Over voltage
Forced air cooling by built-in DC fan
CH4: Polarity is selectable
Fixed switching frequency at 100KHz
3 years warranty
..
SPECIFICATION
MODEL
QP-150-3A
QP-150-3B
QP-150-3C
OUTPUT NUMBER
CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4
DC VOLTAGE
5V
3.3V 12V
-5V
5V
3.3V 12V
-12V 5V
3.3V 15V
-15V
RATED CURRENT
10A
10A
5A
0.6A 10A
10A
5A
0.6A 10A
10A
4A
0.6A
CURRENT RANGE
3 ~ 15A 0 ~ 15A 0.4 ~ 5A 0 ~ 1A 3 ~ 15A 0 ~ 15A 0.4 ~ 5A 0 ~ 1A 3 ~ 15A 0 ~ 15A 0.4 ~ 5A 0 ~ 1A
RATED POWER (max.)
146W
150.2W
152W
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V
VOLTAGE TOLERANCE Note.3 3.0% 3.0% 6.0% 5.0% 3.0% 3.0% 6.0% 5.0% 3.0% 3.0% +8,-6% 5.0%
LINE REGULATION
1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 2.0% 1.0%
LOAD REGULATION
2.0% 2.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0%
SETUP, RISE TIME
800ms, 50ms/230VAC 800ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
24ms/230VAC 24ms/115VAC at full load
VOLTAGE RANGE
90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC PF>0.98/115VAC at full load
INPUT
EFFICIENCY (Typ.)
73%
75%
74%
AC CURRENT (Typ.)
2.5A/115VAC 1.2A/230VAC
INRUSH CURRENT (Typ.) COLD START 40A/230V
LEAKAGE CURRENT
<3.5mA / 240VAC
OVERLOAD
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
CH1:5.75 ~ 6.75V CH2:3.8 ~ 4.4V
Protection type : Shut down o/p voltage, re-power on to recover
95 5 (TSW1)
OVER TEMPERATURE(OPTION) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
-10 ~ +60 (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0~50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note 4) EMC EMISSION
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
MTBF
141.5K hrs min. MIL-HDBK-217F (25 )
OTHERS
NOTE
DIMENSION
199*99*50mm (L*W*H)
PACKING
0.93Kg; 20pcs/19.6Kg/1.28CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:QP-150-SPEC 2011-08-19