QP-1000_09 Datasheet, PDF (1/4 Pages) Mean Well Enterprises Co., Ltd. – 1000W Quad Output Power Supply
1000W Quad Output Power Supply
QP-1000
Features :
Universal AC input / Full range
AC input active surge current limiting
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage/Over temperature
Forced air cooling by built-in DC Fan
Built-in remote ON-OFF function for CH3,CH4 and the whole unit
Isolate output
Built-in remote sense function(CH3,CH4)
Built-in external voltage control function(CH3,CH4)
Built-in output current monitor signal(CH3,CH4)
SPECIFICATION
MODEL
QP-1000
OUTPUT NUMBER
CH1
CH2
CH3
CH4
DC VOLTAGE
12V
5V
24V
24V
RATED CURRENT
8.4A
6A
12.5A
25A
CURRENT RANGE
0 ~ 8.4A
0 ~ 6A
0 ~ 12.5A
0 ~ 25A
130.8W(max.)
RATED POWER (convection)
1000W(max.)
300W
600W
RIPPLE & NOISE (max.) Note.2 120mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
10.8 ~ 13.2V
80mVp-p
4.5 ~ 5.5V
100mVp-p
21.5 ~ 26.5V
200mVp-p
21.5 ~ 26.5V
REMOTE PROGRAMMING (PV) CH3,CH4 10% ~ 120% adjustable by 0.5 ~ 6VDC external control
VOLTAGE TOLERANCE Note.3 2.0%
2.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
1.0%
1.0%
1.0%
1.0%
SETUP, RISE TIME
1500ms, 50ms/230VAC 1500ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load
VOLTAGE RANGE Note.5 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR
PF 0.95/230VAC PF 0.97/115VAC at full load
INPUT EFFICIENCY(Typ.)
86%
AC CURRENT (Typ.)
12A/115VAC 6A/230VAC
INRUSH CURRENT (Typ.) COLD START 25A/115VAC 40A/230VAC
LEAKAGE CURRENT
<2mA / 240VAC
105 ~ 135% rated output power
OVERLOAD
CH1, CH2 : Protection type : Shut down o/p voltage, re-power on to recover
CH3, CH4 : Protection type : Constant current limiting, unit will shut down after 3 sec., re-power on to recover
PROTECTION OVER VOLTAGE
13.8 ~ 16.2V
5.75 ~ 6.75V
30 ~ 34.8V
Protection type : Shut down o/p voltage, re-power on to recover
30~ 34.8V
OVER TEMPERATURE
75 5 detect on heatsink of power transistors
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION
REMOTE CONTROL
CURRENT MONITOR
Turn ON/OFF CH3,CH4 and the whole power supply
RC+/RC-: Short , Power ON ; RC+/RC-: Open , Power OFF
Signal provides an output of 0 ~ 5V which applies over 10 ~ 100% of rated load.
OUTPUT VOLTAGE EXTERNAL CONTROL Please see the Function Manual
WORKING TEMP.
-20 ~ +70 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 45 )
VIBRATION
SAFETY STANDARDS
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
Design refer to UL60950-1,TUV EN60950-1
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22)
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61000-6-2, EN61204-3
MTBF
K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
278*177.8*63.5mm (L*W*H)
PACKING
Kg
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltage. Please check the derating curve for more details.
File Name:QP-1000-SPEC 2008-12-05