English
Language : 

Q-60_10 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 60W Quad Output Switching Power Supply
60W Quad Output Switching Power Supply
Q-60 series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
Fixed switching frequency at 35KHz
2 years warranty
SPECIFICATION
MODEL
Q-60B
Q-60C
Q-60D
OUTPUT NUMBER
CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4
DC VOLTAGE
5V
12V
-5V
-12V 5V
15V
-5V
-15V 5V
12V
24V
-12V
RATED CURRENT
5.5A 2A
0.5A 0.5A 5.5A 1.5A 0.5A 0.5A 4A
1A
1A
0.5A
CURRENT RANGE
0.5 ~ 8A 0.1 ~ 3A 0 ~ 1A 0 ~ 1A 0.5 ~ 8A 0.1 ~ 3A 0 ~ 1A 0 ~ 1A 0.5 ~ 8A 0.1 ~ 3A 0.1 ~ 1.5A 0 ~ 1A
OUTPUT
RATED POWER
60W
60W
62W
RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 100mVp-p 120mVp-p 100mVp-p 120mVp-p 100mVp-p 120mVp-p 100mVp-p 120mVp-p 150mVp-p 120mVp-p
VOLTAGE ADJ. RANGE
CH1: 4.75 ~ 5.5V
CH1: 4.75 ~ 5.5V
CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0% 6.0% 5.0% 5.0% 2.0% +8,-4% 5.0% 5.0% 2.0% 6.0% +8,-4% 5.0%
LINE REGULATION
0.5% 1.0% 0.5% 0.5% 0.5% 2.0% 0.5% 0.5% 0.5% 1.0% 2.0% 0.5%
LOAD REGULATION
0.5% 4.0% 1.0% 1.0% 0.5% 4.0% 1.0% 1.0% 0.5% 4.0% 4.0% 1.0%
SETUP, RISE TIME
800ms, 20ms/230VAC 1600ms, 20ms/115VAC at full load
HOLD UP TIME (Typ.)
70ms/230VAC 15ms/115VAC at full load
VOLTAGE RANGE
85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY (Typ.)
70%
72%
75%
AC CURRENT (Typ.)
2A/115VAC 0.8A/230VAC
INRUSH CURRENT (Typ.) COLD START 15A/115VAC 30A/230VAC
LEAKAGE CURRENT
<1mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
105 ~ 150%/115VAC rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5V: 5.75 ~ 6.75VDC
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 ) on +5V output
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, light industry level, criteria A
MTBF
284.8K hrs min. MIL-HDBK-217F (25 )
DIMENSION
159*97*38mm (L*W*H)
PACKING
0.56Kg; 24pcs/14.4Kg/0.75CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:Q-60-SPEC 2010-10-18