English
Language : 

PS-65_11 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 65W Single Output Switching Power Supply
65W Single Output Switching Power Supply
PS-65 series
Features :
Universal AC input/Full range
Low leakage current<0.5mA
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 65KHz
2 years warranty
SPECIFICATION
MODEL
PS-65-3.3 PS-65-5 PS-65-7.5 PS-65-12 PS-65-13.5 PS-65-15 PS-65-24 PS-65-27 PS-65-48
DC VOLTAGE
3.3V
5V
7.5V
12V
13.5V
15V
24V
27V
48V
RATED CURRENT
12A
12A
8A
5.2A
4.7A
4.2A
2.7A
2.4A
1.35A
CURRENT RANGE
0 ~ 15.2A 0 ~ 13.8A 0 ~ 9.6A 0 ~ 6A
0 ~ 5.4A 0 ~ 4.8A 0 ~ 3A
0 ~ 2.7A 0 ~ 1.5A
RATED POWER
39.6W
60W
60W
62.4W
63.45W
63W
64.8W
64.8W
64.8W
OUTPUT
OUTPUT POWER (max.)
Rated output power for convection; 72W (+3.3V : 50W;+5V:69W) with 18 CFM min. Forced air
RIPPLE & NOISE (max.) Note.2 80mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p
VOLTAGE ADJ. RANGE
3.14 ~ 3.63V 4.75 ~ 5.5V 7.13 ~ 8.25V 11.4 ~ 13.2V 12.8 ~ 14.9V 14.25 ~ 16.5V 22.8 ~ 26.4V 25.65 ~ 29.7V 45.6 ~ 52.8V
VOLTAGE TOLERANCE Note.3 3.0%
3.0%
3.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
LINE REGULATION
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LOAD REGULATION
3.0%
3.0%
3.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
SETUP, RISE TIME
800ms, 20ms at full load
HOLD UP TIME (Typ.)
60ms at full load
VOLTAGE RANGE
90 ~ 264VAC 127 ~370VDC
FREQUENCY RANGE
47 ~ 440Hz
INPUT
EFFICIENCY(Typ.)
AC CURRENT (Typ.)
69%
76%
79%
79%
79%
79%
80%
80%
80%
1.2A/115VAC 0.72A/230VAC
INRUSH CURRENT (Typ.) COLD START 20A/115VAC 40A/230VAC
LEAKAGE CURRENT
<0.75mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
(Note 4)
ISOLATION RESISTANCE
EMC EMISSION
73 ~ 105W(3.3V : 51 ~ 75W)(5V : 70 ~ 105W) rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
3.8 ~ 4.46V 5.75 ~ 6.75V 8.63 ~ 10.1V 13.8 ~ 16.2V 15.5 ~ 18.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 31 ~ 36.45V
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
-10 ~ +60 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.04%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
55.2 ~ 64.8V
OTHERS
NOTE
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
MTBF
300.7K hrs min. MIL-HDBK-217F (25 )
DIMENSION
127*76*42mm (L*W*H)
PACKING
0.21Kg; 54pcs/14.2Kg/1.35CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Mounting holes M1 and M2 should be grounded for EMI purposes.
6. Heat Sink HS1,HS2 can not be shorted.
File Name:PS-65-SPEC 2011-08-18