English
Language : 

PS-35_11 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 35W Single Output Switching Power Supply
35W Single Output Switching Power Supply
PS-35 series
½ Features :
Universal AC input/Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 60KHz
2 years warranty
SPECIFICATION
MODEL
PS-35-3.3
PS-35-5
PS-35-7.5
PS-35-12
PS-35-13.5 PS-35-15
PS-35-24
PS-35-48
OUTPUT
DC VOLTAGE
3.3V
RATED CURRENT
6A
CURRENT RANGE
0 ~ 6A
RATED POWER
19.8W
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE ADJ. RANGE
3.14 ~ 3.63V
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION
0.5%
LOAD REGULATION
1%
5V
6A
0 ~ 6A
30W
100mVp-p
4.75 ~ 5.5V
2.0%
0.5%
1%
7.5V
4.7A
0 ~ 4.7A
35.25W
100mVp-p
7.13 ~ 8.25V
2.0%
0.5%
1%
12V
3A
0 ~ 3A
36W
120mVp-p
10.8 ~ 13.2V
1.0%
0.5%
0.5%
13.5V
2.6A
0 ~ 2.6A
35.1W
120mVp-p
12.15 ~ 14.85V
1.0%
0.5%
0.5%
15V
2.4A
0 ~ 2.4A
36W
150mVp-p
13.5 ~ 16.5V
1.0%
0.5%
0.5%
24V
1.5A
0 ~ 1.5A
36W
200mVp-p
21.6 ~ 26.4V
1.0%
0.5%
0.5%
48V
0.75A
0 ~ 0.75A
36W
240mVp-p
43.2 ~ 52.8V
1.0%
0.5%
0.5%
SETUP, RISE TIME
1200ms, 30ms/230VAC,1200ms,30ms/115VAC at full load
HOLD TIME (Typ.)
50ms/230VAC,10ms/115VAC at full load
VOLTAGE RANGE
90 ~ 264VAC 127 ~370VDC
FREQUENCY RANGE
47 ~ 440Hz
INPUT
EFFICIENCY(Typ.)
70%
78%
80%
81%
81%
81%
85%
84%
AC CURRENT (Typ.)
0.75A/115VAC 0.5A/230VAC
INRUSH CURRENT (Typ.) COLD START 23A/115VAC 45A/230VAC
LEAKAGE CURRENT
<2mA / 240VAC
OVER LOAD
PROTECTION
OVER VOLTAGE
105 ~ 150% rated output power (3.3V:105 ~ 160% rated output power)
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
3.8 ~ 4.95V 5.75 ~ 6.75V 8.63 ~ 10.5V 13.8 ~ 16.2V 15.5 ~ 18.2V 17.25 ~ 20.25V
Protection type : shut down O/P voltage,re-power on to recover
27.6 ~ 32.4V
55.2 ~ 62.4V
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
-20 ~ +65J ( Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85J, 1 0 ~ 95% RH
Ó0 .05%/J ( 0 ~ 50J)
10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes
UL60950, TUV EN60950-1 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMC
(Note 4)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
588.8Khrs
OTHERS
NOTE
DIMENSION
101.6*50.8*24mm (L*W*H)
PACKING
0.124Kg;96PCS/12.9Kg/0.8CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25J of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:PS-35-SPEC 2011-01-28