English
Language : 

PPT-125_10 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 125W Triple Output with PFC Function
125W Triple Output with PFC Function
PPT-125 series
Features :
Universal AC input / Full range
Built-in active PFC function
Protections: Short circuit / Overload / Over voltage
PWM control and regulated
High power density 6.117W/inch3
LED indicator for power on
100% full load burn-in test
125W with 18CFM FAN
5"x3" compact size
3 years warranty
SPECIFICATION
MODEL
PPT-125A
PPT-125B
PPT-125C
PPT-125D
OUTPUT NUMBER
CH1
CH2 CH3
CH1
CH2
CH3
CH1
CH2
CH3
CH1
CH2
CH3
DC VOLTAGE
3.3V 5V
12V
5V
12V
-12V 5V
15V
-15V 5V
24V
12V
RATED CURRENT
10A
8A
0.5A 11.5A 3A
0.5A 11A
2.5A 0.5A 7A
2.5A 0.5A
CURRENT RANGE (convection) 1 ~ 10A 0.8 ~ 8A 0.05 ~ 0.5A 1 ~ 11.5A 0.3 ~ 3A 0.05 ~ 0.5A 1 ~ 11A 0.25 ~ 2.5A 0.05 ~ 0.5A 1 ~ 7A 0.25 ~ 2.5A 0.05 ~ 0.5A
OUTPUT
CURRENT RANGE (18CFM FAN) 1 ~ 12.5A 0.8 ~ 10A 0.05 ~ 0.63A 1 ~ 14.38A 0.3 ~ 3.75A 0.05 ~ 0.63A 1 ~ 13.75A 0.25 ~ 3.13A 0.05 ~ 0.63A 1 ~ 8.75A 0.25 ~ 3.13A 0.05 ~ 0.63A
RATED POWER (convection) 79W
99.5W
100W
101W
RATED POWER (18CFM FAN) 98.8W
124.46W
125.15W
126.43W
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 120mVp-p 100mVp-p 120mVp-p 120mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 240mVp-p 120mVp-p
VOLTAGE ADJ. RANGE
CH1:3.13 ~ 3.46V
CH1:4.75 ~ 5.25V
CH1:4.75 ~ 5.25V
CH1:4.75 ~ 5.25V
VOLTAGE TOLERANCE Note.3 3.0% 5.0% 6.0% 3.0% 5.0% 6.0% 3.0% 5.0% 6.0% 3.0% 5.0% 6.0%
LINE REGULATION
0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5%
LOAD REGULATION
3.0% 3.0% 5.0% 3.0% 3.0% 5.0% 3.0% 3.0% 5.0% 3.0% 3.0% 5.0%
SETUP, RISE TIME
1000ms, 30ms/230VAC 2000ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
24ms/230VAC
90 ~ 264VAC
47~63Hz
24ms/115VAC at full load
127 ~ 370VDC
POWER FACTOR (Typ.)
PF>0.93/230VAC PF>0.98/115VAC at full load
INPUT
EFFICIENCY (Typ.)
75%
78%
78%
78%
AC CURRENT (Typ.)
1.7A/115VAC 0.75A/230VAC
INRUSH CURRENT (Typ.) COLD START 24A/230VAC
LEAKAGE CURRENT
<2mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
130 ~ 160% rated output power
Protection type : Fold back current limiting, recovers automatically after fault condition is removed
CH1:3.6 ~ 4.45V
CH1:5.75 ~ 6.75V
CH1:5.75 ~ 6.75V
CH1:5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
WORKING TEMP., HUMIDITY
WORKING TEMP.
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-20 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.05%/ (0 ~ 50
SAFETY &
EMC
(Note 4)
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
OTHERS
NOTE
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
MTBF
94.7Khrs min. MIL-HDBK-217F (25 )
DIMENSION
127*76.2*34.6mm (L*W*H)
PACKING
0.37Kg; 36pcs/14.3Kg/0.79CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Heat Sink HS1,HS2 & HS3 can not be shorted.
File Name:PPT-125-SPEC 2010-10-18