English
Language : 

PPS-200_11 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 200W Single Output with PFC Function
200W Single Output with PFC Function
PPS-200 series
Features :
Universal AC input / Full range
Built-in active PFC function
High efficiency up to 90% (typ)
Protections: Short circuit / Overload / Over voltage / Over temperature
PWM control and regulated
High power density 9.78W/inch3
5"x3" compact size
Built-in remote sense function
ZVS technology to reduce power dissipation
Free air convection for 150W and 200W with 20.5 CFM forced air
3 years warranty
SPECIFICATION
MODEL
PPS-200-5
PPS-200-12
PPS-200-15
PPS-200-24
PPS-200-27
PPS-200-48
OUTPUT
INPUT
DC VOLTAGE
5V
12V
15V
24V
RATED CURRENT
36A
16.6A
13.3A
8.3A
CURRENT RANGE (convection) 0 ~ 26A
0 ~ 12.5A
0 ~ 10A
0 ~ 6.25A
CURRENT RANGE (20.5CFM FAN) 0 ~ 36A
0 ~ 16.6A
0 ~ 13.3A
0 ~ 8.3A
RATED POWER (convection) 130W
150W
150W
150W
RATED POWER (20.5CFM FAN) 180W
199.2W
199.5W
199.2W
RIPPLE & NOISE (max.) Note.2 100mVp-p
100mVp-p
100mVp-p
150mVp-p
VOLTAGE ADJ. RANGE
4.5 ~ 5.5V
10.8 ~ 13.2V
13.5 ~ 16.5V
21.6 ~ 26.4V
VOLTAGE TOLERANCE Note.3 4.0%
3.0%
3.0%
2.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
1.0%
1.0%
1.0%
1.0%
SETUP, RISE TIME
1200ms, 60ms/230VAC 2500ms, 60ms/115VAC at full load
HOLD UP TIME (Typ.)
11ms/230VAC/115VAC at full load
VOLTAGE RANGE
90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.93/230VAC PF>0.98/115VAC at full load
EFFICIENCY (Typ.)
86%
89%
89%
89%
AC CURRENT (Typ.)
2.2A/115VAC 1.2A/230VAC
INRUSH CURRENT (Typ.) COLD START 70A/230VAC
27V
7.4A
0 ~ 5.56A
0 ~ 7.4A
150W
199.8W
150mVp-p
24.3 ~ 30V
2.0%
0.5%
1.0%
89%
48V
4.167A
0 ~ 3.13A
0 ~ 4.167A
150.24W
200.016W
250mVp-p
43.2 ~ 52.8V
2.0%
0.5%
1.0%
90%
LEAKAGE CURRENT
<2mA / 240VAC
OVERLOAD
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note 4) EMC EMISSION
5.6 ~ 7.25V
13.8 ~ 16.2V
17.25 ~ 20.25V
27.6 ~ 32.4V
31.05 ~ 36.45V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
110 5 (TSW1) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-20 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.05%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
57.6 ~ 67.2V
OTHERS
NOTE
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
MTBF
108.4Khrs min. MIL-HDBK-217F (25 )
DIMENSION
127*76.2*34.6mm (L*W*H)
PACKING
0.37Kg; 36pcs/14.3Kg/0.79CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Heat Sink HS1,HS2 can not be shorted.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
File Name:PPS-200-SPEC 2011-11-29