PPS-125_11 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 125W Single Output with PFC Function
125W Single Output with PFC Function
PPS-125 series
Features :
Universal AC input / Full range
Built-in active PFC function
Protections: Short circuit / Overload / Over voltage
PWM control and regulated
High power density 6.117W/inch3
Built-in remote sense function
LED indicator for power on
100% full load burn-in test
125W with 18CFM FAN
5"x3" compact size
3 years warranty
SPECIFICATION
MODEL
PPS-125-3.3 PPS-125-5 PPS-125-12 PPS-125-13.5 PPS-125-15 PPS-125-24 PPS-125-27 PPS-125-48
DC VOLTAGE
3.3V
5V
12V
13.5V
15V
24V
27V
48V
RATED CURRENT
20A
CURRENT RANGE (convection) 0 ~ 20A
20A
0 ~ 20A
8.5A
0 ~ 8.5A
7.5A
0 ~ 7.5A
6.7A
0 ~ 6.7A
4.2A
0 ~ 4.2A
3.8A
0 ~ 3.8A
2.1A
0 ~ 2.1A
CURRENT RANGE (18CFM FAN) 0 ~ 25A
0 ~ 25A
0 ~ 10.5A
0 ~ 9.3A
0 ~ 8.4A
0 ~ 5.2A
0 ~ 4.6A
0 ~ 2.6A
RATED POWER (convection) 66W
100W
102W
101.25W
100.5W
100.8W
102.6W
100.8W
RATED POWER (18CFM FAN) 82.5W
125W
126W
125.55W
126W
124.8W
124.2W
124.8W
OUTPUT
RIPPLE & NOISE (max.) Note.2 100mVp-p
VOLTAGE ADJ. RANGE
3.13 ~ 3.46V
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION
0.5%
100mVp-p
4.75 ~ 5.25V
2.0%
0.5%
100mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 250mVp-p
11.40 ~ 12.60V 12.82 ~ 14.17V 14.25 ~ 15.75V 22.80 ~ 25.20V 25.65 ~ 28.35V 45.60 ~ 50.40V
2.0%
2.0%
2.0%
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
SETUP, RISE TIME
HOLD UP TIME (Typ.)
1000ms, 30ms/230VAC 2000ms, 30ms/115VAC at full load
24ms/230VAC 24ms/115VAC at full load
VOLTAGE RANGE
90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
47~63Hz
PF>0.93/230VAC
PF>0.98/115VAC at full load
INPUT
EFFICIENCY (Typ.)
70%
79%
80%
80%
80%
83%
83%
84%
AC CURRENT
115VAC 1.2A
1.7A
(Typ.)
230VAC 0.6A
0.75A
INRUSH CURRENT (Typ.) COLD START 24A/230VAC
LEAKAGE CURRENT
<2mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
130 ~ 160% rated output power
Protection type : Fold back current limiting, recovers automatically after fault condition is removed
3.63 ~ 4.45V 5.5 ~ 6.75V 13.8 ~ 16.2V 15.5 ~ 20.25V 17.25 ~ 20.25V 27.6 ~ 32.4V 31.05 ~ 36.45V 57.6 ~ 67.2V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-20 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.05%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC EMISSION
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
MTBF
111.7Khrs min. MIL-HDBK-217F (25 )
DIMENSION
127*76.2*34.6mm (L*W*H)
PACKING
0.37Kg; 36pcs/14.3Kg/0.79CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Heat Sink HS1,HS2 & HS3 can not be shorted.
File Name:PPS-125-SPEC 2011-08-18