English
Language : 

PPQ-1003_12 Datasheet, PDF (1/3 Pages) Mean Well Enterprises Co., Ltd. – 100W Quad Output with PFC Function
100W Quad Output with PFC Function
PPQ-1003 series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at PFC:67KHz PWM:134KHz(Optional)
2 years warranty
SPECIFICATION
MODEL
PPQ-1003A
PPQ-1003B
OUTPUT NUMBER
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
DC VOLTAGE
3.3V
5V
12V
-5V
3.3V
5V
12V
-12V
RATED CURRENT
10A
10A
2A
0.3A
10A
10A
2A
0.3A
CURRENT RANGE
0 ~ 15A
2 ~ 15A
0.2 ~ 3A
0 ~ 1A
0 ~ 15A
2 ~ 15A
0.2 ~ 3A
0 ~ 1A
OUTPUT
RATED POWER
108.5W
RIPPLE & NOISE (max.) Note.2 100mVp-p
VOLTAGE ADJ. RANGE
3.14 ~ 3.63V
VOLTAGE TOLERANCE Note.3 3.0%
LINE REGULATION
1.0%
100mVp-p
4.75 ~ 5.5V
3.0%
1.0%
150mVp-p
------
6.0%
2.0%
100mVp-p
------
6.0%
1.0%
110.6W
100mVp-p
3.14 ~ 3.63V
3.0%
1.0%
100mVp-p
4.75 ~ 5.5V
3.0%
1.0%
150mVp-p
------
6.0%
2.0%
120mVp-p
------
6.0%
1.0%
LOAD REGULATION
2.0%
2.0%
6.0%
1.0%
2.0%
2.0%
6.0%
1.0%
SETUP, RISE TIME
800ms, 50ms at full load
HOLD UP TIME (Typ.)
18ms at full load
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
90 ~ 264VAC 127 ~370VDC
47 ~ 63Hz
PF>0.95/230VAC PF>0.98/115VAC at full load
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
72%
1.65A/115VAC 0.85A/230VAC
COLD START 40A
<1mA /240VAC
OVER LOAD
PROTECTION
OVER VOLTAGE
105% ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
CH1: 3.6 ~ 4.3V CH2: 5.75 ~ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note 4) EMC EMISSION
-10 ~ +60 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
OTHERS
NOTE
MTBF
150.6K hrs min. MIL-HDBK-217F (25 )
DIMENSION
177.8*107.95*40mm (L*W*H)
PACKING
0.62Kg; 24pcs/15.5Kg/1.34CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Heat Sink HS1,HS2 can not be shorted.
File Name:PPQ-1003-SPEC 2012-02-21