English
Language : 

PLP-60_12 Datasheet, PDF (1/3 Pages) Mean Well Enterprises Co., Ltd. – 60W Single Output LED Power Supply
60W Single Output LED Power Supply
PLP-60 series
Features :
Universal AC input / Full range
Protections: Short circuit / Over current / Over voltage
Built-in active PFC function
Cooling by free air convection
Class 2 power unit
Output current level adjustable
100% full load burn-in test
High reliability
Suitable for built-in applications of LED lighting
2 years warranty
SPECIFICATION
( for 48V only)
( except for 48V )
MODEL
PLP-60-12
PLP-60-24
PLP-60-48
OUTPUT
DC VOLTAGE
12V
24V
CONSTANT CURRENT OPERATION VOLTAGE Note.5 9 ~ 12V
18 ~ 24V
RATED CURRENT
5A
2.5A
CURRENT RANGE
0 ~ 5A
0 ~ 2.5A
RATED POWER
60W
60W
RIPPLE & NOISE (max.) Note.2 4.5Vp-p
4.5Vp-p
CURRENT ADJ. RANGE
3.75 ~ 5A
1.875 ~ 2.5A
VOLTAGE TOLERANCE Note.3 10%
LINE REGULATION
3.0%
LOAD REGULATION
5.0%
SETUP TIME
1000ms / 230VAC 2000ms / 115VAC at full load
48V
36 ~ 48V
1.3A
0 ~ 1.3A
62.4W
4.8Vp-p
0.975 ~ 1.3A
VOLTAGE RANGE Note.4 90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF 0.9 at 75 ~ 100% load, 115VAC / 230VAC
INPUT EFFICIENCY (Typ.)
84%
88%
89%
AC CURRENT (Typ.)
0.8A/115VAC 0.4A/230VAC
INRUSH CURRENT (max.) 42A/230VAC
LEAKAGE CURRENT
<0.75mA / 240VAC
OVER CURRENT
PROTECTION SHORT CIRCUIT
OVER VOLTAGE
100 ~ 110%
Note.5
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
15 ~ 18V
28 ~ 35V
57 ~ 63V
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC
EMC EMISSION
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750, TUV EN61347-1, EN61347-2-13, CSA C22.2 No. 250.0-08(except for 48V) approved ; design refer to UL60950-1
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C( 75% load); EN61000-3-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024,EN61547, light industry level, criteria A
MTBF
583.3Khrs min. MIL-HDBK-217F (25 )
OTHERS
NOTE
DIMENSION
101.6*50.8*29.6mm (L*W*H)
PACKING
0.16Kg; 96pcs/16.4Kg/0.89CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
6. Heat sink HS1,HS2 can not be shorted.
7. Heat sink HS1 must have safety isolation distance with system case.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
File Name:PLP-60-SPEC 2012-03-01