SPECIFICATION
MODEL
PLP-20-12
PLP-20-18
PLP-20-24
PLP-20-36
PLP-20-48
OUTPUT
DC VOLTAGE
12V
18V
24V
LED OPERATION VOLTAGE Note.5 9 ~ 12V
13.5 ~ 18V
18 ~ 24V
RATED CURRENT
1.6A
1.1A
0.8A
CURRENT RANGE
0 ~ 1.6A
0 ~ 1.1A
0 ~ 0.8A
CURRENT ADJ. RANGE
75% ~ 100%
RATED POWER
19.2W
19.8W
19.2W
RIPPLE & NOISE (max.) Note.2 2.5Vp-p
3.0Vp-p
3.0Vp-p
VOLTAGE TOLERANCE Note.3 10%
LINE REGULATION
3.0%
LOAD REGULATION
10%
SETUP, RISE TIME
2300ms, 200ms / 230VAC 3000ms, 200ms / 115VAC at full load
36V
27 ~ 36V
0.55A
0 ~ 0.55A
19.8W
3.0Vp-p
48V
36 ~ 48V
0.42A
0 ~ 0.42A
20.2W
3.8Vp-p
VOLTAGE RANGE Note.4 90 ~ 277VAC 127~392VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR
PF>0.9/230VAC
INPUT EFFICIENCY(Typ.)
80%
81%
82%
83%
83.5%
AC CURRENT
0.4A/115VAC 0.2A/230VAC
INRUSH CURRENT(max.) 40A/230VAC
LEAKAGE CURRENT
0.5mA / 240VAC
OVER CURRENT
95 ~ 110%
Note.5
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed.
PROTECTION
OVER VOLTAGE
14 ~ 16V
19 ~ 22V
27 ~ 34V
Protection type : Shut off o/p voltage, clamping by zener diode
41 ~ 46V
OVER TEMPERATURE
110 10 (TSW1)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
-30 ~ +60 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.06%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
TUV EN61347-1, EN61347-2-13, UL8750 approved
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC
SAFETY & ISOLATION RESISTANCE I/P-O/P:100M Ohms/500VDC / 25 / 70%RH
EMC
EMI CONDUCTION & RADIATION Compliance to EN55015
HARMONIC CURRENT
Compliance to EN61000-3-2 Class C( 75% load);EN61000-3-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level, criteria A
MTBF
643.6Khrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
140*32*22(L*W*H)
PACKING
0.12kg;60pcs/9.2kg/0.62CUFT
54 ~ 60V
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage, please check the static characteristic for more details.
5. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
File Name:PLP-20-SPEC 2011-03-09