English
Language : 

PLN-60 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 60W Single Output LED Power Supply
60W Single Output LED Power Supply
PLN-60 series
Features :
Universal AC input / Full range
Fully isolated plastic case with IP64 level
Built-in constant current limiting circuit with adjustable OCP level
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in active PFC function
IP64 design for indoor or outdoor installations
UL1310 Class 2 power unit
Cooling by free air convection
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
2 years warranty
SPECIFICATION
LPS F 110 M M SELV
EQUIVALENT
( for 48V only)
IP64 ( except for 48V )
MODEL
PLN-60-12
PLN-60-15
PLN-60-20
PLN-60-24
PLN-60-27
PLN-60-36
PLN-60-48
OUTPUT
DC VOLTAGE
12V
15V
20V
24V
CONSTANT CURRENT REGION Note.7 8.4 ~ 12V
10.5 ~15V
14 ~ 20V
16.8 ~24V
RATED CURRENT
5A
4A
3A
2.5A
CURRENT RANGE
0 ~ 5A
0 ~ 4A
0 ~ 3A
0 ~ 2.5A
RATED POWER
60W
60W
60W
60W
RIPPLE & NOISE (max.) Note.2 2Vp-p
2.4Vp-p
1.8Vp-p
2.7Vp-p
11 ~ 13V
13.8 ~ 16.2V 18 ~ 22V
VOLTAGE ADJ. RANGE Note.6
Can be adjusted by internal potential meter SVR1
22 ~ 26V
CURRENT ADJ. RANGE Note.6 3% ~ -25%. Can be adjusted by internal potential meter SVR2
VOLTAGE TOLERANCE Note.3 10%
LINE REGULATION
3.0%
LOAD REGULATION
5.0%
SETUP TIME
1500ms / 230VAC 3000ms / 115VAC at full load
27V
18.9 ~27V
2.3A
0 ~ 2.3A
62.1W
2.7Vp-p
25 ~ 30V
36V
25.2 ~ 36V
1.7A
0 ~ 1.7A
61W
3.6Vp-p
32.5 ~ 39V
48V
33.6 ~ 48V
1.3A
0 ~ 1.3A
62.5W
4.6Vp-p
43.6 ~ 51.8V
VOLTAGE RANGE Note.5 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR
PF 0.9 at 75 ~ 100% load, 115VAC / 230VAC
INPUT
EFFICIENCY(Typ.)
83%
84.5%
86.5%
86.5%
87%
87%
88%
AC CURRENT
0.8A/115VAC 0.4A/230VAC
INRUSH CURRENT(max.) 40A/230VAC
LEAKAGE CURRENT
<0.75mA / 240VAC
OVER CURRENT
95 ~ 110%
130% (max)
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT Note.4 Hiccup mode, recovers automatically after fault condition is removed.
PROTECTION OVER VOLTAGE
13.8 ~ 16V
17.5 ~ 21V
22.8 ~ 25V
28 ~ 32V
Protection type : Shut down o/p voltage, re-power on to recover
31 ~ 35V
41 ~ 46V
OVER TEMPERATURE
95 10 (TSW1) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
54 ~ 60V
WORKING TEMP.
-30 ~ +50 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 95% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
UL1310 Class 2, TUV EN61347-1, EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
EMC
EMI CONDUCTION & RADIATION Compliance to EN55015, EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2 Class C ( 75% load) ; EN61000-3-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024,EN61547, light industry level, criteria A
MTBF
497.8Khrs min. MIL-HDBK-217F (25 )
OTHERS
NOTE
DIMENSION
181*61.5*35mm (L*W*H)
PACKING
0.5Kg; 24pcs/13Kg/0.75CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
Direct connecting to LEDs is not suggested for models with “RIPPLE & NOISE” > 10% and using additional drivers is highly recommended.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to OLP characteristics.
5. Derating may be needed under low input voltage. Please check the derating curve for more details.
6. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB.
7. Constant current operation region is within 70% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
File Name:PLN-60-SPEC 2009-03-04