English
Language : 

PLN-45_12 Datasheet, PDF (1/3 Pages) Mean Well Enterprises Co., Ltd. – 45W Single Output LED Power Supply
45W Single Output LED Power Supply
PLN-45 series
Features :
Universal AC input / Full range (up to 295VAC)
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
Built-in constant current limiting circuit with adjustable OCP level
Fully isolated plastic case with IP64 level
Built-in active PFC function
IP64 design for indoor or outdoor installations
Class 2 power unit
Pass LPS
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications (Note.2)
Compliance to worldwide safety regulations for lighting
2 years warranty
LPS F 110 M M SELV
( for 48V only)
IP64 ( except for 48V )
SPECIFICATION
MODEL
PLN-45-12
PLN-45-15
PLN-45-20
PLN-45-24
PLN-45-27
PLN-45-36
PLN-45-48
OUTPUT
INPUT
DC VOLTAGE
12V
15V
20V
24V
27V
36V
48V
CONSTANT CURRENT
OPERATION VOLTAGE
Note.6
9 ~ 12V
11.25 ~15V
15 ~ 20V
18 ~24V
20.25 ~27V
27 ~ 36V
36 ~ 48V
RATED CURRENT
3.8A
3A
2.3A
1.9A
1.7A
1.25A
0.95A
CURRENT RANGE
0 ~ 3.8A
0 ~ 3A
0 ~ 2.3A
0 ~ 1.9A
0 ~ 1.7A
0 ~ 1.25A
0 ~ 0.95A
RATED POWER
45.6W
45W
46W
45.6W
45.9W
45W
45.6W
RIPPLE & NOISE (max.) Note.2 2Vp-p
2.4Vp-p
1.8Vp-p
2.7Vp-p
2.7Vp-p
3.6Vp-p
4.6Vp-p
11.5 ~ 13V
14.5 ~ 16.2V 19.5 ~ 22V
VOLTAGE ADJ. RANGE Note.5
Can be adjusted by internal potentiometer SVR1
24 ~ 26V
25 ~ 30V
32.5 ~ 39V
43.6 ~ 51.8V
CURRENT ADJ. RANGE Note.5 3% ~ -25%. Can be adjusted by internal potentiometer SVR2
VOLTAGE TOLERANCE Note.3 10%
LINE REGULATION
3.0%
LOAD REGULATION
5.0%
SETUP TIME
1500ms / 230VAC 3000ms / 115VAC at full load
VOLTAGE RANGE Note.4 90 ~ 295VAC 127 ~ 417VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.92/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
83.5%
85%
86.5%
86.5%
86.5%
87.5%
87.5%
AC CURRENT (Typ.)
0.55A/115VAC 0.25A/230VAC 0.22A/277VAC
INRUSH CURRENT (max.) 40A/230VAC
LEAKAGE CURRENT
<0.75mA / 240VAC
OVER CURRENT
95 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
PROTECTION OVER VOLTAGE
Hiccup mode, recovers automatically after fault condition is removed.
13.8 ~ 16V
17.5 ~ 21V
22.8 ~ 25V
28 ~ 32V
Protection type : Shut down o/p voltage, re-power on to recover
31 ~ 35V
41 ~ 46V
54 ~ 60V
OVER TEMPERATURE
95 10 (TSW1) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
WORKING HUMIDITY
-30 ~ +50 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
UL879, UL1310, UL8750, CSA C22.2 No. 207-M89(except for 48V), TUV EN61347-1, EN61347-2-13 independent, CAN/CSA
C22.2 No. 223-M91(except for 48V), CSA C22.2 No. 250.0-08(except for 48V), IP64, J61347-1, J61347-2-13 approved, design refer to UL60950-1
SAFETY & WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
EMC
ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
EMC EMISSION
Compliance to EN55015, EN61000-3-2 Class C ( 75% load) ; EN61000-3-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level, criteria A
MTBF
497.8Khrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
181*61.5*35mm (L*W*H)
NOTE
PACKING
0.5Kg; 24pcs/13Kg/0.75CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB.
6. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.