30W Single Output LED Power Supply
PLN-30 series
Features :
Universal AC input / Full range (up to 295VAC)
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
Built-in constant current limiting circuit with adjustable OCP level
Fully isolated plastic case with IP64 level
Built-in active PFC function
IP64 design for indoor or outdoor installations
Pass LPS
Class power unit, no FG
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications (Note.2)
Compliance to worldwide safety regulations for lighting
2 years warranty
LPS F 110 M M SELV
( except for 48V )
( for 48V only)
IP64 ( except for 48V )
SPECIFICATION
MODEL
PLN-30-9 PLN-30-12 PLN-30-15 PLN-30-20 PLN-30-24 PLN-30-27 PLN-30-36 PLN-30-48
OUTPUT
INPUT
DC VOLTAGE
9V
12V
15V
20V
24V
27V
36V
48V
CONSTANT CURRENT REGION Note.6 6.3 ~ 9V
8.4 ~ 12V
10.5 ~ 15V 14 ~ 20V
16.8 ~ 24V 18.9 ~ 27V 25.2 ~ 36V
33.6 ~ 48V
RATED CURRENT
3.3A
2.5A
2A
1.5A
1.25A
1.12A
0.84A
0.63A
CURRENT RANGE
0 ~ 3.3A
0 ~ 2.5A
0 ~ 2A
0 ~ 1.5A
0 ~ 1.25A 0 ~ 1.12A
0 ~ 0.84A
0 ~ 0.63A
RATED POWER
29.7W
30W
30W
30W
30W
30.24W
30.24W
30.24W
RIPPLE & NOISE (max.) Note.2 2.6Vp-p
2Vp-p
2.6Vp-p
2.6Vp-p
2.6Vp-p
2.3Vp-p
4.5Vp-p
3.7Vp-p
VOLTAGE ADJ. RANGE Note.5 -5% ~ 10%. Can be adjusted by internal potentiometer SVR1
CURRENT ADJ. RANGE Note.5 3% ~ -25%. Can be adjusted by internal potentiometer SVR2
VOLTAGE TOLERANCE Note.3 10%
LINE REGULATION
3.0%
LOAD REGULATION
5.0%
SETUP TIME
1500ms / 230VAC 3000ms / 115VAC at full load
VOLTAGE RANGE Note.4 90 ~ 295VAC 127 ~ 417VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
80%
82.5%
83.5%
84%
84%
84.5%
85%
85.5%
AC CURRENT (Typ.)
0.4A/115VAC 0.2A/230VAC
INRUSH CURRENT (max.) 40A/230VAC
LEAKAGE CURRENT
<0.5mA / 240VAC
OVER CURRENT
100 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
Hiccup mode, recovers automatically after fault condition is removed.
10 ~ 14V
14 ~ 16V
17 ~ 22V
23 ~ 26V
27 ~ 34V
Protection type : Shut down o/p voltage, re-power on to recover
31 ~ 35V
40 ~ 50V
53 ~ 63V
OVER TEMPERATURE
95 10 (TSW1)
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
-30 ~ +50 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.06%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
UL879, TUV EN61347-1, EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V) ; J61347-1, J61347-2-13, IP64 approved
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC
EMC EMISSION
I/P-O/P:3.75KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C (pin 25W), Class D (>70% load) ; EN61000-3-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level, criteria A
MTBF
621.4Khrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
PACKING
145*47*30mm (L*W*H)
0.22Kg; 60pcs/14.2Kg/1.25CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Output voltage can be adjusted through the SVR1 on the PCB; limit of output constant current level can be adjusted through the SVR2 on the PCB.
6. Constant current operation region is within 70% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
File Name:PLN-30-SPEC 2011-07-27