English
Language : 

PLN-100_12 Datasheet, PDF (1/3 Pages) Mean Well Enterprises Co., Ltd. – 100W Single Output Switching Power Supply
100W Single Output Switching Power Supply
PLN-100 series
Features :
Universal AC input / Full range (up to 295VAC)
High efficiency up to 88.5%
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
Built-in active PFC function
IP64 design for indoor or outdoor installations
Pass LPS
Class 2 power unit
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
Suitable for dry / damp locations
Compliance to worldwide safety regulations for lighting
2 years warranty
LPS F 110 M M SELV
( for 48V only)
IP64 ( except for 48V )
SPECIFICATION
MODEL
PLN-100-12 PLN-100-15 PLN-100-20 PLN-100-24 PLN-100-27 PLN-100-36 PLN-100-48
OUTPUT
INPUT
DC VOLTAGE
12V
15V
20V
24V
27V
36V
48V
CONSTANT CURRENT REGION Note.6 9 ~ 12V
11.25 ~ 15V
15 ~ 20V
18 ~ 24V
20.25 ~ 27V
27 ~ 36V
36 ~ 48V
RATED CURRENT
Note.5 5A
5A
4.8A
4A
3.55A
2.65A
2A
RATED POWER
Note.5 60W
75W
96W
96W
95.85W
95.4W
96W
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
200mVp-p
VOLTAGE ADJ. RANGE (SVR1) 10.2 ~ 12V
12.8 ~ 15V
17 ~ 20V
20.4 ~ 24V
23 ~ 27V
30.6 ~ 36V
40.8 ~ 48V
CURRENT ADJ. RANGE(SVR2) 3.75 ~ 5A
3.75 ~ 5A
3.6 ~ 4.8A
3 ~ 4A
2.6 ~ 3.55A
2 ~ 2.65A
1.5 ~ 2A
VOLTAGE TOLERANCE Note.3 3.0%
3.0%
3.0%
3.0%
3.0%
2.0%
2.0%
LINE REGULATION
1.0%
LOAD REGULATION
2.0%
SETUP, RISE TIME
1200ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load
HOLD UP TIME (Typ.)
60ms/230VAC 30ms/115VAC at full load
VOLTAGE RANGE Note.4 90 ~ 295VAC 127 ~ 417VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
83%
85%
88.5%
88.5%
88%
88%
88.5%
AC CURRENT (Typ.)
12V:0.8A/115VAC 0.4A/230VAC 0.3A/277VAC 15V:0.9A/115VAC 0.45A/230VAC 0.35A/277VAC
20V ~ 48V:1.1A/115VAC 0.55A/230VAC 0.45A/277VAC
INRUSH CURRENT (Typ.) COLD START 40A/230VAC
LEAKAGE CURRENT
<0.75mA / 240VAC
OVER CURRENT
95 ~ 102%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
Hiccup mode, recovers automatically after fault condition is removed
13 ~ 16V
16.5 ~ 20V
22 ~ 27V
27 ~ 34V
30 ~ 36V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
39 ~ 48V
52 ~ 64V
OVER TEMPERATURE
90 10 (RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
-30 ~ +50 (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 95% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL879, UL1310, UL8750, CSA C22.2 No. 207-M89(except for 48V), TUV EN61347-1, EN61347-2-13 independent, TUV EN60950-1,
SAFETY STANDARDS Note.7
CAN/CSA C22.2 No. 223-M91(except for 48V), CSA C22.2 No. 250.0-08(except for 48V), IP64, J61347-1, J61347-2-13 approved ; design refer to UL60950-1
SAFETY & WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
EMC
ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
EMC EMISSION
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (>75% load) ; EN61000-3-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
MTBF
303.1Khrs min. MIL-HDBK-217F (25 )
OTHERS
NOTE
DIMENSION
200*70.5*35mm (L*W*H)
PACKING
0.52Kg; 20pcs/12.5Kg/0.76CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. This is the maximum possible output current and power. Over load protection may be activated slightly below this level to comply with the requirement
of UL1310 class 2.
6. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
File Name:PLN-100-SPEC 2012-03-12