English
Language : 

PLD-16 Datasheet, PDF (1/3 Pages) Mean Well Enterprises Co., Ltd. – 16W Single Output LED Power Supply
16W Single Output LED Power Supply
PLD-16 series
■ Features :
115VAC or 230VAC models available
Built-in active PFC function
Constant current design
Protections: Short circuit / Over temperature
Cooling by free air convection
Fully isolated plastic case
Class 2 Power Unit
Class Ⅱ power unit, no FG
IP42 design
Suitable for indoor LED lighting applications
100% full load burn-in test
Low cost
High reliability
3 years warranty
F
110
( for B type only)
( for B type only)
( for 350mA)
(except for 350mA)
IP42 SELV
( for A type only) ( for B type only) ( for B type only)
PLD-16-350 A A : With AC input 90~ 135VAC.
B : With AC input 180~ 295VAC.
SPECIFICATION
MODEL
PLD-16-350
PLD-16-700
PLD-16-1050
PLD-16-1400
RATED CURRENT
350mA
700mA
1050mA
1400mA
OUTPUT
OPERATING VOLTAGE RANGE 24 ~ 48V
CURRENT ACCURACY
±5.0%
RATED POWER
16.8W
16 ~ 24V
16.8W
12 ~ 16V
16.8W
8 ~ 12V
16.8W
RIPPLE & NOISE (max.) Note.1 4.6Vp-p
2.7Vp-p
2.2Vp-p
2Vp-p
NO LOAD OUTPUT VOLTAGE (max.) 60V
35V
25V
16V
SETUP TIME
500ms / 230VAC 2000ms / 115VAC at full load
FREQUENCY RANGE
47 ~ 63Hz
INPUT
POWER FACTOR (Typ.)
PF>0.9/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
TOTAL HARMONIC
DISTORTION
A series THD< 20% when output loading≧70% at 115VAC
B series THD< 20% when output loading≧70% at 230VAC input and output loading≧80% at 277VAC input
A series 84.5%
84.5%
84%
EFFICIENCY (Typ.) B series 85.5%
86%
85%
82.5%
83.5%
AC CURRENT (Typ.)
0.4A/115VAC 0.2A/230VAC 0.15A/277VAC
INRUSH CURRENT(Typ.)
COLD START 20A(twidth=25μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs A series 58 units (circuit breaker of type B) / 58 units (circuit breaker of type C) at 115VAC
on 16A CIRCUIT
BREAKER
B series 128 units (circuit breaker of type B) / 128 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
<0.5mA / 240VAC
PROTECTION SHORT CIRCUIT
OVER TEMPERATURE
Hiccup mode, recovers automatically after fault condition is removed.
Shut down o/p voltage, re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-30 ~ +50℃ (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80℃, 10 ~ 95% RH
±0.03%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
UL8750,CSA C22.2 No.250.0-08(except for PLD-16-350);ENEC EN 613471-1,EN 61347-2-13 independent,
EN62384(for B type only), IP42 approved
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC
EMC EMISSION
I/P-O/P:3.75KVAC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55015 (B type only), EN61000-3-2 Class C ; EN61000-3-3, FCC part 18 non-consumer equipment(A type only)
OTHERS
NOTE
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level, criteria A
MTBF
906.5Khrs min. MIL-HDBK-217F (25℃)
DIMENSION
84*57*29.5mm (L*W*H)
PACKING
0.19Kg; 72pcs/14.7Kg/0.92CUFT
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
3. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
File Name:PLD-16-SPEC 2015-08-21