SPECIFICATION
LPS F 110 M M SELV
( for 48V only)
( except for 48V )
MODEL
PLC-60-12
PLC-60-15
PLC-60-20
PLC-60-24
PLC-60-27
PLC-60-36
PLC-60-48
OUTPUT
DC VOLTAGE
12V
15V
20V
CONSTANT CURRENT REGION Note.6 8.4 ~ 12V
10.5 ~15V
14 ~ 20V
RATED CURRENT
5A
4A
3A
CURRENT RANGE
0 ~ 5A
0 ~ 4A
0 ~ 3A
RATED POWER
60W
60W
60W
RIPPLE & NOISE (max.) Note.2 2Vp-p
2.4Vp-p
1.8Vp-p
VOLTAGE ADJ. RANGE Note.5 11.5 ~ 13V
14.5 ~ 16.2V 19.5 ~ 22V
CURRENT ADJ. RANGE Note.5 3.75 ~ 5.15A 3 ~ 4.12A
2.25 ~ 3.09A
VOLTAGE TOLERANCE Note.3 10%
LINE REGULATION
3.0%
LOAD REGULATION
5.0%
SETUP TIME
1500ms / 230VAC 3000ms / 115VAC at full load
24V
16.8 ~24V
2.5A
0 ~ 2.5A
60W
2.4Vp-p
24 ~ 26V
1.875 ~ 2.575A
27V
18.9 ~27V
2.3A
0 ~ 2.3A
62.1W
2.7Vp-p
25 ~ 30V
1.725 ~ 2.369A
36V
25.2 ~ 36V
1.7A
0 ~ 1.7A
61W
3.6Vp-p
32.5 ~ 39V
1.275 ~ 1.751A
48V
33.6 ~ 48V
1.3A
0 ~ 1.3A
62.5W
4.6Vp-p
43.6 ~ 51.8V
0.975 ~ 1.339A
VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.98/115VAC, PF>0.9/230VAC at full load (Please refer to "Power Factor Characteristic" curve)
INPUT EFFICIENCY (Typ.)
85%
86%
87.5%
87%
88%
89%
89%
AC CURRENT (Typ.)
0.8A/115VAC 0.4A/230VAC
INRUSH CURRENT (max.) 40A/230VAC
LEAKAGE CURRENT
<0.75mA / 240VAC
OVER CURRENT
SHORT CIRCUIT
PROTECTION OVER VOLTAGE
95 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed.
13.8 ~ 16V
17.5 ~ 21V
23 ~ 26V
28 ~ 32V
31 ~ 35V
41 ~ 46V
Protection type : Shut down o/p voltage, re-power on to recover
54 ~ 60V
OVER TEMPERATURE
95 10 (TSW1) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-30 ~ +50 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC
EMC EMISSION
EMC IMMUNITY
MTBF
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL1310 Class 2, TUV EN61347-1, EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V) ; J61347-1, J61347-2-13 approved
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 75% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024,EN61547, light industry level, criteria A
515Khrs min. MIL-HDBK-217F (25 )
OTHERS
NOTE
DIMENSION
181.5*62*35mm (L*W*H)
PACKING
0.41Kg; 30pcs/13.3Kg/0.67CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB.
6. Constant current operation region is within 70% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
File Name:PLC-60-SPEC 2011-07-28