English
Language : 

PLC-30 Datasheet, PDF (1/3 Pages) Mean Well Enterprises Co., Ltd. – 30W Single Output LED Power Supply
30W Single Output LED Power Supply
PLC-30 series
Features :
Universal AC input / Full range
Adjustable output voltage and current level
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
Built-in constant current limiting circuit
Fully isolated plastic case with terminal block style of I/O
Built-in active PFC function, comply with EN61000-3-2 class C
(Pin 25W)
Class power unit, no FG
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications (Note.2)
Compliance to worldwide safety regulations for lighting
2 years warranty
SPECIFICATION
F 110 M M SELV
( for 48V only)
( except for 48V )
MODEL
PLC-30-9 PLC-30-12 PLC-30-15 PLC-30-20 PLC-30-24 PLC-30-27 PLC-30-36 PLC-30-48
OUTPUT
DC VOLTAGE
9V
12V
15V
20V
24V
27V
36V
CONSTANT CURRENT REGION Note.6 6.3 ~ 9V
8.4 ~ 12V
10.5 ~ 15V 14 ~ 20V
16.8 ~ 24V 18.9 ~ 27V 25.2 ~ 36V
RATED CURRENT
3.3A
2.5A
2A
1.5A
1.25A
1.12A
0.84A
CURRENT RANGE
0 ~ 3.3A
0 ~ 2.5A
0 ~ 2A
0 ~ 1.5A
0 ~ 1.25A 0 ~ 1.12A
0 ~ 0.84A
RATED POWER
29.7W
30W
30W
30W
30W
30.24W
30.24W
RIPPLE & NOISE (max.) Note.2 2.6Vp-p
2Vp-p
2.6Vp-p
2.6Vp-p
2.4Vp-p
2.3Vp-p
3.6Vp-p
VOLTAGE ADJ. RANGE Note.5 8.55 ~ 9.9V 11.4 ~ 13.2V 14.5 ~ 16.5V 19 ~ 22V
22.8 ~ 26.4V 25.65 ~ 29.7V 34.2 ~ 39.6V
CURRENT ADJ. RANGE Note.5 2.475 ~ 3.399A 1.875 ~ 2.575A 1.5 ~ 2.06A 1.125 ~ 1.545A 0.938 ~ 1.288A 0.84 ~ 1.1536A 0.63 ~ 0.865A
VOLTAGE TOLERANCE Note.3 10%
LINE REGULATION
3.0%
LOAD REGULATION
5.0%
SETUP TIME
1500ms / 230VAC 3000ms / 115VAC at full load
48V
33.6 ~ 48V
0.63A
0 ~ 0.63A
30.24W
3.7Vp-p
45.6 ~ 52.8V
0.473 ~ 0.649A
INPUT
VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/115VAC, PF>0.9/230VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
80%
82.5%
83.5%
84%
84%
84.5%
85%
85.5%
AC CURRENT (Typ.)
INRUSH CURRENT (max.)
0.4A/115VAC 0.2A/230VAC
40A/230VAC
LEAKAGE CURRENT
<0.5mA / 240VAC
OVER CURRENT
100 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
Hiccup mode, recovers automatically after fault condition is removed.
10 ~ 14V
14 ~ 16V
17 ~ 22V
23 ~ 26V
27 ~ 34V
Protection type : Shut down o/p voltage, re-power on to recover
95 10 (TSW1)
Protection type : Shut down o/p voltage, re-power on to recover
31 ~ 35V
40 ~ 50V
53 ~ 63V
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-30 ~ +50 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.06%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY &
EMC
OTHERS
NOTE
SAFETY STANDARDS
UL1310 Class 2, TUV EN61347-1, EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V) ; J61347-1, J61347-2-13 approved
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC
ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
EMC EMISSION
Compliance to EN55015, EN61000-3-2 Class C (Pin 25W), Class D (>70% load) ; EN61000-3-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level, criteria A
MTBF
625.5Khrs min. MIL-HDBK-217F (25 )
DIMENSION
160*46*30mm (L*W*H)
PACKING
0.2Kg; 70pcs/15Kg/0.96CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Output voltage can be adjusted through the SVR1 on the PCB; limit of output constant current level can be adjusted through the SVR2 on the PCB.
6. Constant current operation region is within 70% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
File Name:PLC-30-SPEC 2011-07-28