PID-250_11 Datasheet, PDF (1/4 Pages) Mean Well Enterprises Co., Ltd. – 250W Isolated Dual Output with PFC Function
250W Isolated Dual Output with PFC Function
PID-250
Features :
Universal AC input / Full range
Optional L-Bracket and cover
Isolated output & GND for CH1,CH2
Built-in active PFC function, PF>0.92
Protections:Short circuit / Overload / Over voltage / Over temperature
Remote control for CH1
Peak load 170% for CH1 within 10 sec.
Cooling by free air convection
100% full load burn-in test
3 years warranty
SPECIFICATION
MODEL
PID-250A
PID-250B
PID-250C
PID-250D
OUTPUT NUMBER
CH1
CH2
CH1
CH2
CH1
CH2
CH1
CH2
DC VOLTAGE
12V
5V
24V
5V
36V
5V
48V
5V
OUTPUT
RATED CURRENT
15A(Peak 20A) 5A
9.4A(Peak 16.7A) 5A
CURRENT RANGE
0 ~ 15A
Note.6 (Peak 20A)
0 ~ 5A
0 ~ 9.4A
0 ~ 5A
(Peak 16.7A)
RATED POWER
205W
250.6W
RIPPLE & NOISE (max.) Note.2 120mVp-p 50mVp-p
150mVp-p 50mVp-p
VOLTAGE ADJ. RANGE
10.8 ~ 13.2V 4.75 ~ 5.25V 21.6 ~ 26.4V 4.75 ~ 5.25V
VOLTAGE TOLERANCE Note.3 3.0%
2.0%
2.0%
2.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
1.0%
2.0%
1.0%
2.0%
SETUP, RISE TIME
2500ms, 60ms/115VAC 1200ms, 60ms/230VAC
HOLD UP TIME (Typ.)
30ms at full load
6.3A(Peak 11.1A) 5A
0 ~ 6.3A
0 ~ 5A
(Peak 11.1A)
251.8W
200mVp-p 50mVp-p
32.4 ~ 39.6V 4.75 ~ 5.25V
2.0%
2.0%
0.5%
0.5%
1.0%
2.0%
4.7A(Peak 8.4A) 5A
0 ~ 4.7A
0 ~ 5A
(Peak 8.4A)
250.6W
200mVp-p 50mVp-p
43.2 ~ 52.8V 4.75 ~ 5.25V
2.0%
2.0%
0.5%
0.5%
1.0%
2.0%
VOLTAGE RANGE Note.5 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR
PF 0.92/230VAC PF 0.97/115VAC at full load
INPUT EFFICIENCY(Typ.)
83%
86%
86%
86%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
3A/115VAC 1.5A/230VAC
COLD START 58A/230VAC
<3.5mA / 240VAC
OVERLOAD
CH1: 105 ~ 170% rated output power
Normally work within 10 sec and then shut down, re-power on to recover
Over 180% rated power or short circuit, constant current limiting within 10 sec and then shut down, re-power on to recover
CH2: 101 ~ 150% rated output power
PROTECTION
OVER VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
13.8 ~ 16.2V 5.5 ~ 6.75V 27.6 ~ 32.4V 5.5 ~ 6.75V 40 ~ 48V
5.5~ 6.75V 54 ~ 64.8V 5.5 ~ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover for CH1 ; Hiccup mode, recovers automatically afer fault condition
is removed for CH2(by zener diode clamp)
OVER TEMPERATURE
105 5 detect on heatsink of power transistors
Protection type : Shut down o/p voltage(CH1), recovers automatically after temperature goes down
FUNCTION REMOTE CONTROL
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
(Note 4)
ISOLATION RESISTANCE
EMC EMISSION
CN52 : Open=CH1 & CH2 power on ; Short = CH1 power off, CH2 power on; when CH2 is malfunction, CH1 will be shut down
-20 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.05%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, period for 60min each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
OTHERS
NOTE
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2, heavy industry level, criteria A
MTBF
150.4Khrs min. MIL-HDBK-217F (25 )
DIMENSION
PCB:222*95*40mm (L*W*H) ; with optional CASE:250*105.4*53mm (L*W*H)
PACKING
PCB:0.74Kg; 18pcs/14.3Kg/0.88CUFT ; with optional CASE:1.6Kg; 9pcs/15.4Kg/0.61CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltage. Please check the derating curve for more details.
6. Peak current should reduce to 150% of rated value if the input voltage <110VAC.
7. Heat Sink HS1,HS2,HS3 can not be shorted.
File Name:PID-250-SPEC 2011-08-18