English
Language : 

PD-110_11 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 110W Dual Output Switching Power Supply
110W Dual Output Switching Power Supply
PD-110 series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
With power good signal output(Optional)
100% full load burn-in test
Fixed switching frequency at 45KHz
2 years warranty
SPECIFICATION
MODEL
PD-110A
PD-110B
OUTPUT NUMBER
CH1
CH2
CH1
CH2
DC VOLTAGE
5V
12V
5V
24V
RATED CURRENT
5A
6.5A
5A
3.5A
CURRENT RANGE
0.5 ~ 5A
0.5 ~ 6.5A
0.5 ~ 5A
0.5 ~ 3.5A
OUTPUT
RATED POWER
103W
RIPPLE & NOISE (max.) Note.2 100mVp-p
VOLTAGE ADJ. RANGE
CH1:4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION
1.0%
150mVp-p
6.0%
2.0%
109W
100mVp-p
CH1:4.75 ~ 5.5V
2.0%
1.0%
200mVp-p
6.0%
2.0%
LOAD REGULATION
1.0%
5.0%
1.0%
5.0%
SETUP, RISE TIME
1200ms, 50ms at full load
HOLD UP TIME (Typ.)
80ms at full load
INPUT
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
100 ~ 264VAC 141 ~370VDC (90 ~ 100VAC 90% load max.)
47 ~ 63Hz
75%
78%
3A/115VAC 1.5A/230VAC
COLD START 40A
<1mA /240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
105% ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75VDC
Protection type : Hiccup mode, recovers automatically after fault condition is removed
WORKING TEMP.
-10 ~ +50 ,60 with cooling fan(Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,11; ENV50204, light industry level, criteria A
MTBF
323K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
177.8*107.95*46mm (L*W*H)
PACKING
0.51Kg; 24pcs/13.1Kg/1.19CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Heat Sink HS1,HS2 can not be shorted.
File Name:PD-110-SPEC 2011-03-31