English
Language : 

PCD-16_12 Datasheet, PDF (1/4 Pages) Mean Well Enterprises Co., Ltd. – 16W Single Output AC Dimmable LED Power Supply
16W Single Output AC Dimmable LED Power Supply
PCD-16 series
F 110
( for B type only)
( for B type only)
SELV IP30
Features :
AC phase-cut dimming
Work with leading edge and trailing edge TRIAC dimmers
115VAC or 230VAC models available
Built-in active PFC function
Constant current design
Protections: Short circuit / Over temperature
Cooling by free air convection
Fully isolated plastic case
IP30 design
Class power unit, no FG
Class 2 power unit
Suitable for indoor LED lighting applications
100% full load burn-in test
Low cost
High reliability
3 years warranty
( for A type only)
( for PCD-16-350 )
( except PCD-16-350 )
( for B type only)
PCD-16-350 A A : With AC input 90~ 135VAC.
B : With AC input 180~ 295VAC.
SPECIFICATION
MODEL
PCD-16-350
PCD-16-700
PCD-16-1050
PCD-16-1400
RATED CURRENT
350mA
700mA
1050mA
1400mA
OUTPUT
OPERATING VOLTAGE RANGE 24 ~ 48V
CURRENT RANGE
0 ~ 350mA
CURRENT ACCURACY
5.0%
RATED POWER
16.8W
16 ~ 24V
0 ~ 700mA
16.8W
12 ~ 16V
0 ~ 1050mA
16.8W
8 ~ 12V
0 ~ 1400mA
16.8W
RIPPLE & NOISE (max.) Note.1 4.6Vp-p
NO LOAD OUTPUT VOLTAGE (max.) 63V
2.7Vp-p
35V
2.2Vp-p
25V
2Vp-p
16V
SETUP TIME
1000ms / 230VAC 2000ms / 115VAC at full load
INPUT
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT(max.)
47 ~ 63Hz
PF>0.9/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
82%
81%
80.5%
80%
0.4A/115VAC 0.2A/230VAC
40A/230VAC
LEAKAGE CURRENT
<0.5mA / 240VAC
SHORT CIRCUIT
PROTECTION
OVER TEMPERATURE
Hiccup mode, recovers automatically after fault condition is removed.
95 10 (RTH1)
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-30 ~ +60 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
UL8750, CSA C22.2 No. 250.0-08(except for PCD-16-350, PCD-25-350, PCD-25-700), ENEC EN 613471,
EN 61347-2-13(for B type only), IP30 approved ; design refer to UL60950-1, TUV EN60950-1, EN61347-1, EN61347-2-13
SAFETY & WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC
EMC
ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
EMC EMISSION
Compliance to EN55015 (B type only), EN61000-3-2 Class C ; EN61000-3-3, FCC part 18 non-consumer equipment (A type only)
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024,EN61547, light industry level, criteria A
MTBF
906.5Khrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
84*57*29.5mm (L*W*H)
PACKING
0.19Kg; 72pcs/14.7Kg/0.92CUFT
NOTE
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
File Name:PCD-16-SPEC 2012-03-20