English
Language : 

PB-600 Datasheet, PDF (1/5 Pages) Mean Well Enterprises Co., Ltd. – 600W Single Output Battery Charger
600W Single Output Battery Charger
PB-600 series
Features :
2/3/8 stage charging (Note 4)
Universal AC input / Full range
Built-in active PFC function PF>0.95
Protection: Reverse polarity / Short circuit / Over voltage / Over temperature
Charger for lead-acid batteries
3 color LED loading indicator
Built-in remote ON-OFF control
Built-in temperature compensation function
Built-in fan speed control (depends on charging current)
3 years warranty
..
SPECIFICATION
MODEL
PB-600-12
PB-600-24
PB-600-48
BOOST CHARGE VOLTAGE 14.4V
28.8V
57.6V
OUTPUT
FLOAT CHARGE VOLTAGE 13.8V
RECOMMENDED BATTERY
135 ~ 400AH
CAPACITY(AMP HOURS)(Note 3)
BATTERY TYPE
Open & Sealed Lead Acid
27.6V
70 ~ 210AH
55.2V
35 ~ 105AH
OUTPUT CURRENT
40A
21A
10.5A
VOLTAGE RANGE
90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
86%
87%
89%
INPUT
POWER FACTOR (Typ.)
0.95/230VAC 0.98/115VAC at full load
AC CURRENT (Typ.)
6.8A/115VAC 3.4A/230VAC
INRUSH CURRENT (Typ.) 25A/115VAC 50A/230VAC
LEAKAGE CURRENT
<3.5mA / 240VAC
OVER VOLTAGE
PROTECTION
16 ~ 18V
32 ~ 35V
Protection type : Shut down o/p voltage, re-power on to recover
64.5 ~ 69.5V
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
REMOTE CONTROL
Open: Normal work Short: Stop Charging
LEAKAGE CURRENT FROM BATTERY (Typ.) 1mA
FUNCTION FAST CHARGE
CHARGING OK
2 / 3 / 8 stage selectable
Relay contact (RY15)
OUTPUT OK
Relay contact (RY13)
TEMPERATURE SENSE By NTC
WORKING TEMP.
-20 ~ +60 (refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.05%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL1012, TUV EN60335-1, EN60335-2-29 (except for 48V), EN60950-1(48V only) approved
SAFETY &
EMC
(Note 2)
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.8KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22)
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024; light industry level, criteria A
OTHERS
MTBF
DIMENSION
PACKING
135.6Khrs min. MIL-HDBK-217F (25 )
230*158*67mm(L*W*H)
2.2Kg; 6pcs/14.2Kg/1.76CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
3. This is Mean Well's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.
4. Please choose the "3 stage" selection when the charger is used to charge the batteries and power the loads in the same time.
File Name:PB-600-SPEC 2011-04-20