English
Language : 

P50A-T Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 46.5~50WAC-DC Triple Output Desktop
46.5~50W AC-DC Triple Output Desktop
P50A-T series
Features :
3 pole AC inlet IEC320-C14
Class power (with earth pin)
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
Fix switching frequency and regulation
Topology: PWM 3882 circuit
LED indicator for power on
Approvals: UL / CUL / TUV / CB / CE
1 year warranty
SPECIFICATION
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
ORDER NO.
P50A13A-R1B
P50A13D-R1B
P50A14E-R1B
OUTPUT
SAFETY MODEL NO.
PSU50A-13A
DC VOLTAGE
Note.2 5V
12V
-5V
RATED CURRENT
4A
2A
0.5A
CURRENT RANGE
0.5 ~ 4.0A 0.5 ~ 2.0A 0.1 ~ 0.5A
RATED POWER
46.5W
RIPPLE & NOISE (max.) Note.3 50mVp-p 100mVp-p 100mVp-p
VOLTAGE ADJ. RANGE
Fixed
VOLTAGE TOLERANCE Note.4 6.0%
10%
12%
LINE REGULATION Note.5 1.0%
1.0%
1.0%
LOAD REGULATION Note.6 5.0%
10%
10%
SETUP, RISE, HOLD UP TIME 1.5s, 50ms, 12ms at full load
PSU50A-13D
5V
12V
4A
2A
0.5 ~ 4.0A 0.5 ~2.0A
50W
50mVp-p 100mVp-p
6.0%
10%
1.0%
1.0%
5.0%
10%
-12V
0.5A
0.1 ~0.5A
100mVp-p
12%
1.0%
10%
PSU50A-14E
5V
15V
4A
1.5A
0.5 ~ 4.0A 0.5 ~ 1.5A
50W
50mVp-p 100mVp-p
6.0%
10%
1.0%
1.0%
5.0%
10%
-15V
0.5A
0.1 ~ 0.5A
100mVp-p
12%
1.0%
10%
VOLTAGE RANGE
FREQUENCY RANGE
90 ~ 264VAC 135~ 370VAC
47 ~ 63Hz
EFFICIENCY (Typ.)
70%
72%
74%
INPUT
AC CURRENT
1.6A / 100VAC
INRUSH CURRENT (max.) 40A / 230VAC
LEAKAGE CURRENT (max.) 0.75mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
150 ~ 250% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5V: 110 ~ 140% of rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
0 ~ +40 (Refer to output load derating curve)
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03% / (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL1950, CSA22.2, EN60950-1 approved
SAFETY &
EMC
(Note. 7)
WITHSTAND VOLTAGE
I/P-O/P:3KVAC , I/P-FG:1.5KVAC
ISOLATION RESISTANCE I/P-O/P,I/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55022(CISPR22) class B
HARMONIC CURRENT
Compliance to EN61000-3-2,3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,11, ENV50204, light industry level, criteria A
MTBF
280K hrs min. MIL-HDBK-217F (25 )
OTHERS
CONNECTOR
DIMENSION
PACKING
PLUG
CABLE
147*76*43mm (L*W*H)
0.55kg; 36pcs / 21kg / CARTON
Standard type R1B: DIN 5PIN for stock ; Other type available by customer requested
Standard type AWM2464 18Awg*4c with shiell 4ft for stock ; Other type available by customer requested
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerence: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load.
7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:P50A-T-SPEC 2007-05-14