English
Language : 

P40B Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 15~40WAC-DC Single Output Desktop
15~40W AC-DC Single Output Desktop
P40B series
Features :
2 pole AC inlet IEC320-C8
Class power (without earth pin)
Full output 3~48V safety approval
Protections: Short circuit / Overload / Over voltage / Over temp.
Fully enclosed plastic case
Fix switching frequency and regulation
Topology: Top switch circuit
LED indicator for power on
Approvals: UL / CUL / TUV / CB / CE
2 years warranty
SPECIFICATION
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
ORDER NO.
P40B-0P2J P40B-1P2J P40B-1-1P2J P40B-2P2J P40B-3P2J P40B-4P2J P40B-5P2J P40B-6P2J P40B-8P2J
SAFETY MODEL NO.
PSU40B-0 PSU40B-1 PSU40B-1-1 PSU40B-2 PSU40B-3 PSU40B-4 PSU40B-5 PSU40B-6 PSU40B-8
DC VOLTAGE
Note.2 3.3V
5V
RATED CURRENT
4.54A
5A
7.5V
9V
12V
15V
18V
24V
48V
4A
3.88A
3.33A
2.66A
2.22A
1.66A
0.83A
CURRENT RANGE
0 ~ 4.54A 0 ~ 5A
0 ~ 4A
0 ~3.88A 0 ~ 3.33A 0 ~ 2.66A 0 ~ 2.22A 0 ~ 1.66A 0 ~ 0.83A
RATED POWER
15W
25W
30W
35W
40W
40W
40W
40W
40W
OUTPUT
RIPPLE & NOISE (max.) Note.3 50mVp-p 50mVp-p 80mVp-p
VOLTAGE ADJ. RANGE
3 ~ 5V
5 ~ 6V
6 ~ 8V
Fixed output by internal VR
VOLTAGE TOLERANCE Note.4 10%
6.0%
5.0%
LINE REGULATION Note.5 1.0%
1.0%
1.0%
LOAD REGULATION Note.6 8.0%
5.0%
5.0%
SETUP, RISE, HOLD UP TIME 200ms, 50ms, 16ms at full load
80mVp-p
8 ~ 11V
5.0%
1.0%
4.0%
80mVp-p
11 ~ 13V
4.0%
1.0%
3.0%
100mVp-p 100mVp-p 150mVp-p 150mVp-p
13 ~ 16V 16 ~ 21V 21 ~ 27V 33 ~ 48V
3.0%
3.0%
3.0%
2.0%
1.0%
1.0%
1.0%
1.0%
2.0%
2.0%
2.0%
1.0%
VOLTAGE RANGE
90 ~ 264VAC 135 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY (Typ.)
AC CURRENT
65%
70%
72%
74%
75%
78%
78%
80%
82%
1A / 100VAC
INRUSH CURRENT (max.) 60A / 230VAC
LEAKAGE CURRENT (max.) 0.25mA / 240VAC
OVERLOAD
150 ~ 450% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
110 ~ 140% rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
IC1Tj135
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
0 ~ +40 (Refer to output load derating curve)
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03% / ( 0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL1950, CSA22.2, EN60950-1 approved
SAFETY &
EMC
(Note. 7)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:3KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022(CISPR22) class B
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,11, ENV50204, light industry level, criteria A
500khrs min. MIL-HDBK-217F (25 )
OTHERS
CONNECTOR
DIMENSION
PACKING
PLUG
CABLE
108*67*36mm (L*W*H)
0.3kg; 54pcs / 20kg / CARTON
Standard type P2J: 2.1 * 5.5 * 11mm, center positive for stock; Other type available by customer requested
Standard type see page2 ; Other type available by customer requested
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerence: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 0% to 100% rated load.
7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:P40B-SPEC 208-05-08