English
Language : 

P25A-T Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 25WAC-DC Triple Output Desktop
25W AC-DC Triple Output Desktop
P25A-T series
Features :
3 pole AC inlet IEC320-C14
Class power (with earth pin)
Protections: Short circuit / Overload / Over voltage / Over temp.
Fully enclosed plastic case
Fix switching frequency and regulation
Topology: Top switch circuit
LED indicator for power on
Approvals: UL / CUL / TUV / CB / CE
1 year warranty
SPECIFICATION
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
ORDER NO.
P25A13A-R1B
P25A13D-R1B
P25A14E-R1B
SAFETY MODEL NO.
PSU25A-13A
PSU25A-13D
PSU25A-14E
DC VOLTAGE
Note.2 5V
12V
-5V
5V
12V
-12V
5V
15V
-15V
RATED CURRENT
2.5A
0.8A
0.3A
2.5A
0.8A
0.3A
2.5A
0.5A
0.3A
CURRENT RANGE
0.5 ~ 2.5A 0.1 ~ 0.8A 0.1 ~ 0.3A 0.5 ~ 2.5A 0.1~0.8A 0.1 ~0.3A 0.5 ~ 2.5A 0.1 ~ 0.5A 0.1 ~ 0.3A
RATED POWER
25W
25W
25W
OUTPUT
RIPPLE & NOISE (max.) Note.3 50mVp-p 100mVp-p 100mVp-p
VOLTAGE ADJ. RANGE
Fixed
VOLTAGE TOLERANCE Note.4 5.0%
5.0%
3.0%
LINE REGULATION Note.5 1.0%
1.0%
1.0%
LOAD REGULATION Note.6 4.0%
4.0%
2.0%
SETUP, RISE, HOLD UP TIME 200ms, 50ms, 16ms at full load
50mVp-p
5.0%
1.0%
4.0%
100mVp-p 100mVp-p 50mVp-p
5.0%
3.0%
5.0%
1.0%
1.0%
1.0%
4.0%
2.0%
4.0%
100mVp-p 100mVp-p
5.0%
3.0%
1.0%
1.0%
4.0%
2.0%
VOLTAGE RANGE
90 ~ 264VAC 135 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
70%
72%
74%
INPUT
AC CURRENT
0.8A / 100VAC
INRUSH CURRENT (max.) 60A / 230VAC
LEAKAGE CURRENT (max.) 0.75mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
150 ~ 250% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
110 ~ 140% rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
0 ~ +40 (Refer to output load derating curve)
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03% / (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL1950, CSA22.2, EN60950-1 Approved
SAFETY &
EMC
(Note. 7)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:3KVAC , I/P-FG:1.5KVAC
I/P-O/P,I/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022(CISPR22) class B
Compliance to EN61000-3-2,3 class A
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,11, Light industry level, criteria A
MTBF
520K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
108*67*36mm (L*W*H)
PACKING
0.3kg ; 54pcs/ 20kg / CARTON
PLUG
CONNECTOR
CABLE
Standard type R1B: DIN 5PIN for stock ; Other type available by customer requested
Standard type UL2464 18AWG*3C 20AWG*2C shield wire *1C with 5fts length for stock ; Other type available by customer requested
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load.
7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:P25A-T-SPEC 2007-03-01