English
Language : 

NET-75 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 75W Triple Output Switching Power Supply
75W Triple Output Switching Power Supply
NET-75 series
Features :
Universal AC input / Full range
Protections: Short circuit / Over load / Over voltage
Cooling by free air convection
100% full load burn-in test
2 years warranty
SPECIFICATION
MODEL
NET-75A
NET-75B
NET-75C
NET-75D
OUTPUT NUMBER
CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3
DC VOLTAGE
5V
12V
-5V
5V
12V
-12V 5V
15V
-15V 5V
24V
12V
RATED CURRENT
6A
3A
0.5A 5A
2.8A 0.5A 6A
2.3A 0.5A 5A
1.5A 1A
CURRENT RANGE Note.6 0.6 ~ 7A 0.2 ~ 3.5A 0.1 ~ 0.7A 0.6 ~ 7A 0.2 ~ 3.5A 0.1 ~ 0.7A 0.6 ~ 7A 0.1 ~ 3.5A 0.1 ~ 0.7A 0.6 ~ 6A 0.1 ~ 2A 0.1 ~ 1.5A
OUTPUT
RATED POWER
68.5W
64.6W
72W
73W
RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 120mVp-p 80mVp-p 120mVp-p 120mVp-p 80mVp-p 150mVp-p 150mVp-p 80mVp-p 200mVp-p 120mVp-p
VOLTAGE ADJ. RANGE
CH1:4.75 ~ 5.5V
CH1: 4.75 ~ 5.5V
CH1: 4.75 ~ 5.5V
CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0% 6.0% 5.0% 2.0% 6.0% 5.0% 2.0% 8.0% 5.0% 2.0% 8.0% 6.0%
LINE REGULATION Note.4 0.5% 1.0% 1.0% 0.5% 1.0% 1.0% 0.5% 1.0% 1.0% 0.5% 1.0% 1.0%
LOAD REGULATION Note.5 1.5% 3.0% 1.0% 1.5% 3.0% 1.0% 1.5% 3.0% 1.0% 1.5% 3.0% 3.0%
SETUP, RISE TIME
500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)
50ms/230VAC 10ms/115VAC at full load
VOLTAGE RANGE
85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY(Typ.)
77%
78%
78%
80%
AC CURRENT (Typ.)
1.5A/115VAC 0.9A/230VAC
INRUSH CURRENT (Typ.) COLD START 45A
LEAKAGE CURRENT
<2mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
-20 ~ +60 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 45 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, CB(IEC60950-1) Approved
SAFETY &
EMC
(Note 6)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1 Light industry level, criteria A
MTBF
OTHERS DIMENSION
361.6K hrs min. MIL-HDBK-217F (25 )
159*97*38mm (L*W*H)
NOTE
PACKING
0.52Kg; 30pcs/16.6Kg/0.97CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:NET-75-SPEC 2006-12-27