English
Language : 

NES-75_11 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 75W Single Output Switching Power Supply
75W Single Output Switching Power Supply
NES-75 series
Features :
Universal AC input/Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
2 years warranty
SPECIFICATION
MODEL
NES-75-5
NES-75-12
NES-75-15
NES-75-24
NES-75-48
DC VOLTAGE
5V
12V
15V
24V
48V
RATED CURRENT
14A
6.2A
5A
3.2A
1.6A
CURRENT RANGE
0 ~ 14A
0 ~ 6.2A
0 ~ 5A
0 ~ 3.2A
0 ~ 1.6A
RATED POWER
70W
74.4W
75W
76.8W
76.8W
OUTPUT
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE ADJ. RANGE
4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION Note.4 0.5%
LOAD REGULATION Note.5 0.5%
SETUP, RISE TIME
500ms, 30ms/230VAC
120mVp-p
150mVp-p
10.8 ~ 13.2V
13.5 ~ 16.5V
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
1200ms, 30ms/115VAC at full load
200mVp-p
21.6 ~ 26.4V
1.0%
0.5%
0.5%
240mVp-p
43.2 ~ 52.8V
1.0%
0.5%
0.5%
HOLD UP TIME (Typ.)
50ms/230VAC 10ms/115VAC at full load
VOLTAGE RANGE
85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY (Typ.)
77%
82%
83%
86%
87%
AC CURRENT (Typ.)
1.5A/115VAC 0.9A/230VAC
INRUSH CURRENT (Typ.) COLD START 45A
LEAKAGE CURRENT
<2mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
105 ~ 135%
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25
27.6 ~ 32.4V
Protection type : Shut down o/p voltage, re-power on to recover
55.2 ~ 64.8V
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
(Note 6)
ISOLATION RESISTANCE
EMC EMISSION
-20 ~ +60 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 45 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CB(IEC60950-1),CCC GB4943 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
OTHERS
EMC IMMUNITY
MTBF
DIMENSION
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-1, light industry level, criteria A
378.2K hrs min. MIL-HDBK-217F (25 )
159*97*38mm (L*W*H)
NOTE
PACKING
0.52Kg; 30pcs/16.6Kg/0.97CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:NES-75-SPEC 2011-08-17