100W Single Output Switching Power Supply
NES-100 series
Features :
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
2 years warranty
SPECIFICATION
MODEL
NES-100-5
NES-100-7.5 NES-100-9
NES-100-12
NES-100-15
NES-100-24
NES-100-48
DC VOLTAGE
5V
7.5V
9V
12V
15V
24V
48V
RATED CURRENT
20A
13.6A
11.2A
8.5A
7A
4.5A
2.3A
CURRENT RANGE
0 ~ 20A
0 ~ 13.6A
0 ~ 11.2A
0 ~ 8.5A
0 ~ 7A
0 ~ 4.5A
0 ~ 2.3A
RATED POWER
100W
102W
100.8W
102W
105W
108W
110.4W
RIPPLE & NOISE (max.) Note.2 80mVp-p
120mVp-p
120mVp-p
120mVp-p
120mVp-p
120mVp-p
150mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
4.75 ~ 5.5V
7.13 ~ 8.3V
8.55 ~ 9.9V
11.4 ~ 13.2V
VOLTAGE TOLERANCE Note.3 2.0%
1.0%
1.0%
1.0%
LINE REGULATION Note.4 0.5%
0.5%
0.5%
0.5%
LOAD REGULATION Note.5 0.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME
500ms, 20ms/230VAC 500ms, 20ms/115VAC at full load
14.25 ~ 16.5V
1.0%
0.5%
0.5%
22.8 ~ 26.4V
1.0%
0.5%
0.5%
45.6 ~ 52.8V
1.0%
0.5%
0.5%
HOLD UP TIME (Typ.)
30ms/230VAC 25ms/115VAC at full load
VOLTAGE RANGE
85 ~ 132VAC / 176 ~ 264VAC selected by switch 248 ~ 373VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY (Typ.)
80%
81%
81%
83%
84%
86%
86%
AC CURRENT (Typ.)
2A/115VAC 1.2A/230VAC
INRUSH CURRENT (Typ.) COLD START 36A
LEAKAGE CURRENT
<2mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.75V 8.6 ~ 10.1V
10.4 ~ 12.2V 13.8 ~ 16.2V 17.25 ~ 20.25V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
27.6 ~ 32.4V
55.2 ~ 64.8V
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-20 ~ +60 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note 6) EMC EMISSION
UL60950-1, CB(IEC60950-1),CCC GB4943 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-1, light industry level, criteria A
OTHERS
NOTE
MTBF
320.7Khrs min. MIL-HDBK-217F (25 )
DIMENSION
159*97*38mm (L*W*H)
PACKING
0.55Kg; 30pcs/17.5Kg/0.97CUFT
1. All parameters not specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:NES-100-SPEC 2011-08-17