100W Dual Output Switching Power Supply
NED-100 series
Features :
AC input range selectable by switch
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
2 years warranty
SPECIFICATION
MODEL
NED-100A
NED-100B
NED-100C
NED-100D
OUTPUT NUMBER
CH1
CH2
CH1
CH2
CH1
CH2
CH1
CH2
DC VOLTAGE
5V
12V
5V
24V
12V
5V
24V
5V
RATED CURRENT
10A
4.2A
8A
2.5A
7A
3A
3.5A
3A
CURRENT RANGE Note.6 2 ~ 10A
0.7 ~ 7.0A 1 ~ 10A
0.3 ~ 3.5A 0 ~ 8A
0 ~ 3A
0 ~ 4A
0 ~ 3A
RATED POWER
100.4W
100W
99W
99W
OUTPUT
RIPPLE & NOISE (max.) Note.2 80mVp-p
120mVp-p
VOLTAGE ADJ. RANGE
CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0%
10%
LINE REGULATION Note.4 0.5%
0.5%
LOAD REGULATION Note.5 1.0%
5.0%
80mVp-p 200mVp-p
CH1: 4.75 ~ 5.5V
2.0%
8.0%
0.5%
0.5%
1.0%
4.0%
120mVp-p 80mVp-p
CH1: 11.4 ~ 13.2V
2.0%
3.0%
0.5%
0.5%
1.0%
2.0%
120mVp-p
80mVp-p
CH1: 22.8 ~ 26.4V
2.0%
3.0%
0.5%
0.5%
1.0%
2.0%
SETUP, RISE TIME
2000ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load
HOLD TIME (Typ.)
25ms/230VAC 20ms/115VAC at full load
VOLTAGE RANGE
88 ~ 132VAC / 176 ~ 264VAC selected by switch
248 ~ 373VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY (Typ.)
80%
82%
80%
82%
AC CURRENT (Typ.)
2A/115VAC 1.2A/230VAC
INRUSH CURRENT (Typ.) COLD START 45A
LEAKAGE CURRENT
<2mA / 240VAC
OVER LOAD
PROTECTION
OVER VOLTAGE
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75V
CH2: 5.75 ~ 6.75V
CH1: 13.8 ~ 15.8V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH2: 27.6 ~ 32.4V
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
-20 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
0.03%/ (0 ~ 50 )on Ch1 output
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CB(IEC60950-1) Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMC
(Note 7)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024,EN61000-6-1,light industry level, criteria A
MTBF
OTHERS DIMENSION
320.7K hrs min. MIL-HDBK-217F (25 )
199*98*38mm (L*W*H)
NOTE
PACKING
0.55Kg; 30pcs/17.5Kg/0.97CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:NED-100-SPEC 2008-09-25