English
Language : 

MWP-610P Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 304W Triple Output for Video Game
304W Triple Output for Video Game
MWP-610P
Features :
230VAC input only
Built-in passive PFC, PF>0.7
Economical video game power
Power ON-OFF switch
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC fan
100% full load burn-in test
2 years warranty
SPECIFICATION
MODEL NO.
MWP-610P
OUTPUT
INPUT
CHANNEL
CH1
DC VOLTAGE
5V
MINIMUM CURRENT
1.5A
RATED CURRENT (CONTINUOUS) 8A
PEAK CURRENT (10 min.) 8A
RATED POWER (CONTINUOUS) 244W
PEAK POWER (10 min.)
304W
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE TOLERANCE
5.0%
LINE REGULATION
1.0%
LOAD REGULATION Note.3 5.0%
HOLD UP TIME
12ms min. at full load
AC RECEPTACLE RATED (max.) 1A / 230VAC
VOLTAGE RANGE
200 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.7 / 230VAC
EFFICIENCY (Typ.)
76%
AC CURRENT
4.5A / 230VAC
INRUSH CURRENT (max.) 80A / 230VAC
LEAKAGE CURRENT(max.) 3.5mA / 240VAC
CH2
12V
1A
8A
12A
150mVp-p
5.0%
1.0%
5.0%
CH3
24V
0.5A
4.5A
5A
200mVp-p
5.0%
1.0%
5.0%
OVERLOAD
PROTECTION
OVER VOLTAGE
105 ~ 200% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
105 ~ 140% rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-10 ~ +50 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.05% / ( 0 ~ 50
10 ~ 200Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
Design refer to EN60950-1
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
I/P-O/P, I/P-FG:1.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG:50M Ohms / 500VDC / 25
EMI CONDUCTION & RADIATION Compliance to EN55022 Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
/ 70% RH
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
CONNECTOR
See page 2
OTHERS COOLING
Forced air ventilation by 8cm DC fan
DIMENSION
150*140*86mm (L*W*H)
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Load regulation is measured from 20% to 100% max. Load.
4. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives.
File Name: MWP-610P-SPEC 2010-04-28