English
Language : 

MWP-606A Datasheet, PDF (1/1 Pages) Mean Well Enterprises Co., Ltd. – 104W Triple Output Switching Power Supply
104W Triple Output Switching Power Supply
MWP-606(A)
Features :
Universal AC input/Full range
Protections:Short circuit/Over load
Cooling by free air convection
2 years warranty
SPECIFICATION
MODEL
MWP-606(A)
OUTPUT NUMBER
CH1
CH2
CH3
DC VOLTAGE
5V
12V
-5V
RATED CURRENT
15A
2A
1A
CURRENT RANGE
3 ~ 15A
0.2 ~ 4A
0.1 ~ 1A
OUTPUT
RATED POWER
104W
RIPPLE & NOISE (max.) Note.2 50mVp-p
VOLTAGE ADJ. RANGE
CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION
0.5%
120mVp-p
8.0%
1.0%
60mVp-p
10%
1.0%
LOAD REGULATION
1.0%
6.0%
8.0%
SETUP, RISE, HOLD TIME 200ms, 50ms, 16ms at full load
INPUT
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT (max.)
88 ~ 132VAC/176 ~ 264VAC selected by switch
47 ~ 63Hz
75%
2.6A/115VAC 1.3A/230VAC
COLD START 20A/115VAC 40A/230VAC
124 ~ 370VDC
LEAKAGE CURRENT
<0.5mA / 240VAC
PROTECTION OVER LOAD
FUNCTION OPERATING DISPLAY
105 ~ 150% rated output power
Protection type : Fold back current limiting, recovers automatically after fault condition is removed
Double color LED correct Range: Green(5~5.4Vref.); Wrong Range: Red
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-10 ~ +60
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.05%/ (0 ~ 50 ) on +5V output
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG :100M Ohms/500VDC
EMC
(Note 4)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61555-2,-3
OTHERS
EMS IMMUNITY
MTBF
DIMENSION
PACKING
Compliance to IEC801-2,3,4, Light industry level, criteria A
348.3K hrs min. MIL-HDBK-217F (25 )
180*110*50mm (L*W*H) 203*115*50mm(L*W*H) with terminal & fixed iron
0.9Kg; 16pcs/15.4Kg/0.95CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:MWP-606(A)-SPEC 2004-12-01