English
Language : 

MWP-602A Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – SWITCHING POWER SUPPLY ISO-9001 CERTIFIED MANUFACTURER
MEAN WELL
SWITCHING POWER SUPPLY
ISO-9001 CERTIFIED MANUFACTURER
MWP-602(A)
(53020)
MWP-606(A)
.LOW COST, HIGH RELIABILITY
.COMPACT SIZE, LIGHT WEIGHT
.105ºC OUTPUT CAPACITOR
.100% FULL LOAD BURN-IN TEST
.INTERNATIONAL AC INPUT RANGE
.OUTPUT VOLTAGE CORRECTION LED
.BUILT IN EMI FILTER, LOW RIPPLE NOISE
.HIGH EFFICIENCY, LOW WORKING TEMPERATURE
.SOFT-START CIRCUIT, LIMITING AC SURGE CURRENT
.SHORT CIRCUIT, OVERLOAD PROTECTED
SPECIFICATION
MODEL
DC OUTPUT VOLTAGE
OUTPUT V. TOLERANCE
OUTPUT RATED CURRENT
OUTPUT CURRENT RANGE
RIPPLE & NOISE
LINE REGULATION
LOAD REGULATION
DC OUTPUT POWER
EFFICIENCY
DC VOLTAGE ADJ.
MWP-602/MWP-602A/(53020)
CH1
CH2
CH3
5V
±2%
15A
3-15A
50mVp-p
±0.5%
±1%
12V
±8%
2A
0.2-3A
120mVp-p
±1%
±6%
104W
75%
CH1:4.7~5.8Vref.
-5V
±10%
1A
0.1-1A
60mVp-p
±1%
±8%
MWP-606/MWP-606A
CH1
CH2
CH3
5V
±2%
15A
3-15A
50mVp-p
±0.5%
±1%
12V
±8%
2A
0.2-4A
120mVp-p
±1%
±6%
104W
75%
CH1:4.75~5.5Vref.
-5V
±10%
1A
0.1-1A
60mVp-p
±1%
±8%
INPUT VOLTAGE RANGE
88~132VAC / 176~264VAC SELECTED BY SWITCH 47~63Hz; 240~370VDC
AC CURRENT
INRUSH CURRENT
LEAKAGE CURRENT
2.6A/115V 1.3A/230V
COLD START 20A/115V 40A/230V
<0.5mA/240VAC
OVERLOAD PROTECTION
105%~150% TYPE:FOLDBACK CURRENT SHUTDOWN RESET:RE-POWER ON
OVER VOLTAGE PROTECTION
OPERATING DISPLAY
TEMP. COEFFICIENT
SETUP, RISE, HOLD UP TIME
VIBRATION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP., HUMIDITY
STORAGE TEMP., HUMIDITY
DIMENSION
WEIGHT
SAFETY STANDARDS
EMC STANDARDS
----------
602A, 606A DOUBLE COLOR LED CORRECT RANGE:GREEN(5~5.4Vref.) WRONG RANGE:RED
±0.05% / ºC (0~50ºC) ON +5V OUTPUT
200ms, 50ms, 16ms
10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms
-10ºC~+60ºC(REFER TO OUTPUT DERATING CURVE), 20%~90% RH
-20ºC~+85ºC, 10%~95% RH
180*110*50mm CASE:602 203*115*50mm WITH TERMINAL & FIXED IRON
0.9Kgs
MEET UL1012 REQUIREMENT (NOT APPLY FOR
THE MARK)
UL1950, TUV EN60950 APPROVED
---------
CISPR22 (EN55022) CLASS B, IEC801-2,3,4,
IEC555-2 VERIFICATION
NOTE :
1.ALL PARAMETERS ARE SPECIFIED AT 230VAC INPUT, RATED LOAD, 25ºC 70% RH. AMBIENT.
2.TOLERANCE GINCLUDE SET UP TOLERANCE, LINE REGULATION, LOAD REGULATION.
3.RIPPLE & NOISE ARE MEASURED AT 20MHz BY USING A 12" TWISTED PAIR TERMINATED WITH A 0.1uF & 47uF CAPACITOR.
4.LINE REGULATION IS MEASURED FROM LOW LINE TO HIGH LINE AT RATED LOAD.
5.LOAD REGULATION IS MEASURED FROM 20% TO 100% RATED LOAD, AND OTHER OUTPUT AT 60% RATED LOAD.
6.EACH OUTPUT PROVIDE UP TO MAXIMUM CURRENT, BUT TOTAL LOAD CAN NOT EXCEED MAX. OUTPUT POWER.
JUN.09.98