SPECIFICATION
MODEL
MSP-300-3.3 MSP-300-5 MSP-300-7.5 MSP-300-12 MSP-300-15 MSP-300-24 MSP-300-36 MSP-300-48
DC VOLTAGE
3.3V
5V
7.5V
12V
15V
24V
36V
48V
RATED CURRENT
60A
60A
40A
27A
22A
14A
9A
7A
CURRENT RANGE
0 ~ 60A
0 ~ 60A
0 ~ 40A
0 ~ 27A
0 ~ 22A
0 ~ 14A
0 ~ 9A
0 ~ 7A
RATED POWER
198W
300W
300W
324W
330W
336W
324W
336W
RIPPLE & NOISE (max.) Note.2 80mVp-p
90mVp-p
100mVp-p 120mVp-p 150mVp-p 150mVp-p 250mVp-p 250mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
2.8 ~ 3.8V
¡Ó VOLTAGE TOLERANCE Note.3 2.5%
LINE REGULATION
¡Ó0.5%
LOAD REGULATION
¡Ó1.0%
4.3 ~ 5.8V
¡Ó2.0%
¡Ó0.5%
¡Ó1.0%
6.8 ~ 9V
¡Ó2.0%
¡Ó0.5%
¡Ó1.0%
10.2 ~ 13.8V
¡Ó1.0%
¡Ó0.3%
¡Ó0.5%
13.5 ~ 18V
¡Ó1.0%
¡Ó0.3%
¡Ó0.5%
21.6 ~ 28.8V
¡Ó1.0%
¡Ó0.2%
¡Ó0.5%
28.8 ~ 39.6V
¡Ó1.0%
¡Ó0.2%
¡Ó0.5%
40.8 ~ 55.2V
¡Ó1.0%
¡Ó0.2%
¡Ó0.5%
SETUP, RISE TIME
1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load
VOLTAGE RANGE Note.5 85 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
120 ~ 370VDC
POWER FACTOR (Typ.)
PF>0.95/230VAC PF>0.99/115VAC at full load
INPUT EFFICIENCY (Typ.)
80%
82%
86%
88%
88%
87%
88%
89%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
4.5A/115VAC 2.25A/230VAC
35A/115VAC 70A/230VAC
£g £g Earth leakage current < 450 A/264VAC , Touch leakage current < 100 A/264VAC
OVERLOAD
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE
PROTECTION
OVER TEMPERATURE
3.96 ~ 4.62V 6 ~ 7V
9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V
Protection type : Shut down o/p voltage, re-power on to recover
¢J¡Ó ¢J 90 5 (TSW1: detect on heatsink of power transistor)
¢J¡Ó ¢J ¢J¡Ó ¢J 100 5 for 3.3V,5V,7.5V ; 95 5 for others (TSW2: detect on heatsink of power diode)
41.4 ~ 48.6V
5V STANDBY
¡Ó Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
5VSB : 5V@0.3A ; tolerance 5%, ripple : 50mVp-p(max.)
FUNCTION
DC OK SIGNAL
REMOTE CONTROL
FAN CONTROL (Typ.)
WORKING TEMP.
PSU turns on : 3.3 ~ 5.6V ; PSU turns off : 0 ~ 1V
RC+ / RC-: 4 ~ 10V or open = power on ; 0 ~ 0.8V or short = power off
¡Ó ¡Ù ¢J Load 35 15% or RTH2 50 Fan on
¢J -40 ~ +70 (Refer to "Derating Curve")
¢J WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
¡Ó ¢J ¢J 0.03%/ (0 ~ 50 )
57.6 ~ 67.2V
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY &
EMC
(Note 4)
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
ANSI/AAMI ES60601-1, IEC60601-1 approved
I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
¢J I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55011 (CISPR11) Class B, EN61000-3-2,-3
EMC IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11, EN60601-1-2
¢J 176Khrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
199*105*41mm (L*W*H)
NOTE
PACKING
0.95Kg;15pcs/15.3Kg/0.69CUFT
¢J 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. No load power consumption<0.5W when RC- & RC+ (CN100 pin4,6) 0 ~ 8V or short.
File Name:MSP-300-SPEC 2012-05-29