English
Language : 

MPS-30 Datasheet, PDF (1/2 Pages) Total Power International – 30W Single Output for Medical Type
30W Single Output for Medical Type
MPS-30 series
Features :
Universal AC input / Full range
Low leakage current 0.3mA
Protections: Short circuit / Overload / Over voltage / Over temperature
Fixed switching frequency at 100KHz
Low cost
High reliability
3 years warranty
SPECIFICATION
EN60601-1
IEC60601-1
MODEL
MPS-30-5
MPS-30-12
MPS-30-15
MPS-30-24
MPS-30-27
MPS-30-48
OUTPUT
DC VOLTAGE
5V
12V
15V
RATED CURRENT
5A
2.5A
2A
CURRENT RANGE
0 ~ 5A
0 ~ 2.5A
0 ~ 2A
RATED POWER
25W
30W
30W
RIPPLE & NOISE (max.) Note.2 80mVp-p
120mVp-p
150mVp-p
VOLTAGE TOLERANCE Note.3 3.0%
3.0%
3.0%
LINE REGULATION
1.0%
1.0%
0.5%
LOAD REGULATION
2.0%
1.0%
1.0%
SETUP, RISE TIME
500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)
70ms/230VAC 12ms/115VAC at full load
24V
1.2A
0 ~ 1.2A
28.8W
240mVp-p
3.0%
0.5%
1.0%
27V
1.1A
0 ~ 1.1A
29.7W
240mVp-p
3.0%
0.5%
1.0%
48V
0.6A
0 ~ 0.6A
28.8W
240mVp-p
2.0%
0.5%
1.0%
VOLTAGE RANGE
88 ~ 264VAC auto switch 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY (Typ.)
72%
75%
76%
77%
78%
78%
AC CURRENT (Typ.)
0.8A/115VAC 0.5A/230VAC
INRUSH CURRENT (Typ.) COLD START 30A/230VAC
LEAKAGE CURRENT
<0.3mA / 264VAC
OVERLOAD
Above 105% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
5.5 ~ 6.75V
13.2 ~ 16.2V
16.5 ~ 20.25V
26.4 ~ 32.4V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Tj 135 typically (U1) detect on main control IC
Protection type : Shut down o/p voltage, re-power on to recover
29.7 ~ 36.45V
52.8 ~ 64.8V
WORKING TEMP.
-10 ~ +60 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL2601-1, TUV EN60601-1, IEC60601-1 approved
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:SHORT
I/P-O/P, I/P-FG:100M Ohms/500VDC
Compliance to EN55011 (CISPR11) Class B
Compliance to EN61000-3-2,-3
OTHERS
NOTE
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, medical level, criteria A
MTBF
547Khrs min. MIL-HDBK-217F (25 )
DIMENSION
101.6*65.8*23.5mm (L*W*H)
PACKING
0.16Kg; 90pcs/15.8Kg/1.02CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:MPS-30-SPEC 2008-03-25